How we can convert H.P into KW or Vice versa

Answer Posted / senthil

1hp=746 watts

kw=1000*746

Is This Answer Correct ?    2 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How much pf maintan in dg set in 6o% load,when Dg runnig Neutaal Earthing removed what happen.

1535


power transmission pole used one support , that only for support or earthing

1433


The specific heats of the gas at constant pressure and constant volume are respectively 1.0 kJ/kg K and 0.72 kJ/kg K; the value of R for the gas is

710


Installation method of self treated earth electrode.

1499


why sometime we get electrical shock while touching the ballon of dish tv connection ? which we should not get.

1530






plz send me the procedure and syllabus for mseb exam

3432


can you please send me the technical questions and aptitude questions of honeywell and jindal steel electrical engg. question paper my e-mail ID is(kkesavanraj@gmail.com)

1551


In constant power region of 3-phase IM torque-speed characteristics, if frequency increases slip A does not alter B decreases C increases D none of above

1585


What is the difference between electronic regulator and ordinary rheostat regulator for fans?

580


what is the requirement regarding earthing of Single conductor with AWA

1668


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

1679


sir,in our plant we r using SATEC PM172E power reading meeters in HT panel side it is monitoring the MB data smart viewer(sever).but last one week we did not get readings inthe server only available in meeter.tell me how communicate meter and server. and also what steps we take for checking.

1793


what is the basic construction diffrance between servo motor ans sqiralcage induction motor

2022


Which device of PlC does share load between DG sets when DG are running in perallel?

1565


if we have a industrial load of 400 kilowatts with 415 volt AC then how much total harmonic distortion (thd%) should be acceptable for steady power system.

1581