How we can convert H.P into KW or Vice versa
Answer Posted / senthil
1hp=746 watts
kw=1000*746
Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
How much pf maintan in dg set in 6o% load,when Dg runnig Neutaal Earthing removed what happen.
power transmission pole used one support , that only for support or earthing
The specific heats of the gas at constant pressure and constant volume are respectively 1.0 kJ/kg K and 0.72 kJ/kg K; the value of R for the gas is
Installation method of self treated earth electrode.
why sometime we get electrical shock while touching the ballon of dish tv connection ? which we should not get.
plz send me the procedure and syllabus for mseb exam
can you please send me the technical questions and aptitude questions of honeywell and jindal steel electrical engg. question paper my e-mail ID is(kkesavanraj@gmail.com)
In constant power region of 3-phase IM torque-speed characteristics, if frequency increases slip A does not alter B decreases C increases D none of above
What is the difference between electronic regulator and ordinary rheostat regulator for fans?
what is the requirement regarding earthing of Single conductor with AWA
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
sir,in our plant we r using SATEC PM172E power reading meeters in HT panel side it is monitoring the MB data smart viewer(sever).but last one week we did not get readings inthe server only available in meeter.tell me how communicate meter and server. and also what steps we take for checking.
what is the basic construction diffrance between servo motor ans sqiralcage induction motor
Which device of PlC does share load between DG sets when DG are running in perallel?
if we have a industrial load of 400 kilowatts with 415 volt AC then how much total harmonic distortion (thd%) should be acceptable for steady power system.