A dc motor running on dc drive whose input is 3ph AC what
will happen if we change the phase sequence of dc drive for
e.g (R Y B) is connect as R B Y, will the motor run as same
as previously running before changing phase without any effect
Answer Posted / nimda
The dc drive may not work at all if you connect your input
power with wrong phase sequence because the firing pulses to
the thyristors will be in wrong sequence. So the motor may
not start at all. There are different types of dc motors but
usually the direction of rotation doesn't change by changing
the polarity at the power source. To change the direction of
rotation you must usually swap either the polarity of the
field winding or the polarity of the rotor winding.
| Is This Answer Correct ? | 1 Yes | 1 No |
Post New Answer View All Answers
How do I calculate a WTI CT ofa 1250kVA 6600/400V transformer
Enlist four components of electrive drives.
What are the different towers used in 132kv transmission line? what are the differences between the P,R,S towers used in 132KV and detailed explanation
Whether it is possible to measure energy at the input of rectifier transformer (12 pulse with very high odd harmonics)
what is the difference between delta delta and star delta connection transformer? why we use delta delta transformer since it need earthing transformer for grounding?
How to calculate cable rating for 3 phase supply?
how to discharge 3 phase power factor correction capacitors
why single phase to grd test in HV cable?why not 2 phase at a time?
how wecalculate breaking capcity of acb mcb mccb .explain with example
Why field rheostat is kept in minimum position?
what is the difference between RMS & TRUE RMS VOLTAGE
Explain dc generator with its types?
Why efficiency in thermal power plant is low?
How to do cable sizing calculation for 750 A Neutral Earthing resistor for 33kv. the 33kv cable going to swbd. is 630mm2 3 runs.
what is mathed of check the D.C MOTOR 181 KW (ARMATURE AND FIELD) WHAT IS THE MATHED OF CHECK THE THYRISTOR MODULE (HIGH CURRENT)