Answer Posted / subhash chand
low pressure, high pressure, oil pressure, chilled water
line and condenser water line flow switches, anti freaze
temp. safety
| Is This Answer Correct ? | 16 Yes | 5 No |
Post New Answer View All Answers
Z transform is use when system is not a) converges b) diverges
What is the difference between a Root Locus plot and a Bode plot?
i want design of D.C.MOTOR 1HP 960RPM AND 2HP 960RPM ITS URRGENT
what is the eight bit unit?
by what factor the starting current is used when comparing star and delta connection for motor starting?
1.what is the difference between transformer differential and busbar differential.2)why we are using 2 slope for trafo diif and 1 slope for busbar diff.3)what is the purpose of metrosil and stabilizing resistor in high impedance relay circuit.4)how metrosil reduce the peak volage.5)what is the funtion of stabilizing resistor
what is the difference between droop mode and ischnorous mode in thermal powerplant?
hi can anyone pls tell me the eee interview core questions asked in l&t
what are the preventive maintanance actions taken for air circuit breaker? please answer me
what are the effects when a salient pole alternator is run at high speed like 3000 r.p.m?
What is an iron loss or core loss pi?
what is transient stability analysis means?
we use capister for power factor. when we use capaciter in dg circuit than defect dg. can we use capaciter bank for dg circuit
What is the difference between rated and per unit in transformer?
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.