Though transformer consist winding which usually cause
reactive power change in both generator and motor but it
wont affect reactive power passing through transformer why?
Answer Posted / vijendra joglekar
The questions itself wrong because the transformer doesnt
consumes real power because there is no rotating part in it
it only introduce working flux but if you take the
generator or motor it will consumes the real power
| Is This Answer Correct ? | 5 Yes | 0 No |
Post New Answer View All Answers
What are locations arc protection relay is fixed.
What is the use of lag compensator?
working principle of oil startar
Make a list observation on Transformer?
Why 3 phase induction motor getting supply in body if one of it's phase is cut
why we used dc supply for field in dg set
diff b/w elcb and rccb
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
I have a drawing of a wound rotor induction motor for a crane. This crane motor has 5 forward speeds & 5 reverse speed implemented of course with different amount of resistance for each speed setting selected. What has got me scratching around is the fact that 8 of the 10 speed selections switch in uneven (unbalanced) amounts of resistances on each of the 3 connections to the motor's rotor.Can this be possible? I would have assumed this would produce unbalanced rotor currents and therefore vibration in the motor. I would greatly appreciate anyone's comments on this. Many thanks, Confused.
Hi I'm doing my MBA(3rd semester).I applied for the post of ET conducted by BHEL the last year.I cleared the written and lost in personal interview.Again I wrote the exam this time and cleared the written n yet to take the personal interview.Shall I disclose in the interview about my studies.What shall i say if they ask about my change from studies to job
how many single tension hardware are required on a double circuit transmission tower?
How is efficiency of DG set calculated? At many places I found the efficiency to be mentioned in percentage. But at some other places I found kWH/ litres. I want to know how dimensionless percentage value is arrived at?
List the time domain specifications.
Dear friends, i would like to know that what is the exact function of 'exciter winding' & 'aux winding' in Alternator?
How to set a Zone 1 distance relay for distribution feeder?