Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is principal of karl ficher instrument!

Answer Posted / nandkishor

The method is based on stoichiometric reaction between water
and a solution of sulfur dioxide and iodine in pyridine(or
any other base)and methanol the end point is detected
electrometrically

Is This Answer Correct ?    6 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

which situation gc hs and gc als require to use?

793


calibrtion procedue of LC-MS

2712


How to calculate coreletion coefficient

1715


How to fix the sample conc. in Related substances test by HPLC?

1099


analytical method validation require to with respect to release specification or shelf life specification?

796


if rsd failed then what require to do?

841


If inhouse hplc related substance method is completly diffrent from Usp for finished proďuct with diffrent impurities then how require to prove method equivalecy?

776


Loss of linearity in tkn analysis, possible reasons?

1322


give clarity of linearity and range in method validation

2420


WHICH STANDARD WE USE IN SILICA ANALYSIS IN SILICA-GEL METHOD FOR SOLID SAMPLE

2134


Please tell me about the pH of Polycaboxylic ether is it in the 5-6 range ever or more than 6

2609


what is mean by peak intigrity?

954


using gradient pressure in gas chromatography are not ?using gradient pressure why

3391


can i use hplc detector to uplc and why?

2293


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1599