Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why is the earth pin in a 3-pin plug the longest and the
thickest?

Answer Posted / mukesh jangra

Because when it insert into the socket first of all it
grounded the ckt or equipment so that third pin of 3-pin
plug is longest.Due to this it avoid from shock to person
& give safety.
The reason of thickness of 3rd pin is low resistance.
Because area depends upon length & thickness.If aera is
large means resistance of that body is less.So due to low
resistance the thickness of 3rd pin is large other than.

Is This Answer Correct ?    14 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the difference between earth fault protection of motor feeder with CBCT and Without CBCT ?

3005


I am having a 1500 KVA transformer whose secondary current is 2086A and my connected load is 1000 KVA, I am having 400 KVAR APFCR for PF improvement what ratio of CT should i install in LT EB Bus to get optimum PF improvement?

1798


11kV capacitor bank of rating 2.4KVAR, is charged with protective relays of only over current & Earth fault &.......without Over Voltage, Under Voltage & Neutral Displacement Relay. Is it advisable??

1660


Can we convert off line transformer to on line transformer

2027


When calculating the speed of a rotor required for a particular frequency of synchronous generator we use the equation 60f/p Is this p is the number of pole pairs of rotor & do we consider the number of pole pairs in the stator is 1?

2062


A parallel flow heat exchanger will perform better than a counter flow heat exchanger. State if the statement is true or false.

1325


How to select, design,size & calculate for 11 KV/33KV/66KV/132KV/220 KV/440 KV circuit breaker for HT side of transformer protection/HT distribution protection?

2815


What is the size of a 60 watt and 80 watt tubelight?

2210


how to determine motor size for a fan application?

2360


what is mean by D.O. in distribution line poles?

1758


How phase to phase voltage comes 440V.

2176


What is earth system using on the floater TN-S or TT. Iam not sure and what ICCP

1797


Thumb rule of cable size(rm>30 rm)X multiplying factor=ampere

1672


what happens when series resonance occurs?

1933


Leakage current,un balance current which relay using for high voltage transmission?

2212