What is the detail function of I/O card in DCS ? Why we
dont use the I/O directly with controller?
Answer Posted / surendra singh tanwar
I/O are required to convert the process value or status in
to a formet which can be communicated to the controller and
v/v controller to processe
| Is This Answer Correct ? | 15 Yes | 0 No |
Post New Answer View All Answers
NPN transistor, SCR, Zener diode, LED, Varactor diode, Vortex meter, RTD, Resistor, Crystal
We are using Rosemount 5400 series Radar Level Transmitters in all types of Sump Applications having oily water hdrocarbon petrochemical nature. What we are facing the problem frequently is that always getting reading frezzed at some value. If we do power recycling , sometimes it is working . then making same freezing problem. If anybody faced before such type of problem and also having solution , Please give the answer.
What is zener diode? What is voltage regulator?
What are the charcterstics of a P&ID controller block for Governor speed raise or lower for a load sharing functionality between 4 Gas turbines in droop mode.
How we can check the 2 wire proxy switch? & how it is connected to DI MODULE OF PLC?
I need control valve ISA hand book. Is there any site to download that big book containing all the pages. Written by Paul Friedmann
what is the process for double acting cylinder pneumatic for 32' v/v
Drum level tx with GP4 with zero elevation:7300mmh20 on HP and 8050mmh2o on LP as range but on commissioning the tx readiing is max,Why this reading?
How vortex sensor used for steam flow measurment can be checked on line i.e without taking out from process line.
WHAT IS THE DIFF. BETWEEN SKIN TEMPERATURE AND PASSES TEMPERATURE..?
What denotes the 5/8mm in the 3300XL 5/8mm proximitor probe?
I m appointed as an automation trainee engineer in small firm in that I am only the one , my company give me a project on s7-200 as i m beginner I don't know how to program so please send me the helpful site so that I complete my project before deadline....please help me out in this critical situation.
I am using 971 Enraf radar level transmitter for LPG tanks ,the tank side indicator gives the error code 999999999FL can any body give me any diagnostic for this issue?
Give an example where you had aproblem on the job, and tell me how you solved the problem. and the finalvoutcome.
1)How many tpes of vibration probe and how many tpyes of vibration. 2)how we can calibrate a vibration probe with tk3 3)what is RMS value in vibration measuring application and how we calculate it.