what is the difference between auto tuning and manual tuning
of controllers(eg:PID,PI,PD CONTROLLERS )
Answer Posted / mahesh kumar
In Autotuning the loop (PID, PIED etc.)are tuned with help
of the S/W, only by pressing the autotune button the S/W
autometically tune the gains while manual tuning the
programmer set all the gains manually. Manual Tuning is
just like hit & Trial Process.
| Is This Answer Correct ? | 8 Yes | 3 No |
Post New Answer View All Answers
1.what is the effect of vapour presuure in orifice plate flow measurement 2.which is more effective 2 pressure sensors or one single differential pressure sensor in orifice plate measurement 3.how to design a v/i converter and i/v converter 4.how many type of thermocouple are there 5.how many leads are there in thermocouple measurement 6.how pressure sensors are connected in level measurement in differential pressure method 7.what is the output of capacitive pressure sensor (ac or dc),how its o/p is signal charactarized 8.what is the physical meaning of discharge coeeficient,why it is calculated,orifice plate what is its value,why it is less than 1,Q at upstream is equal to or not equal to Q at downstream of orifice plate why?what is vena contracta in orifice plate 9.why rotameter is called variable area flowmeter,it can measure flow even if area is not varying,why it is made tapered 10.design a 10 bit counter ,which counter you will prefer 11.how to remove self heating error in RTD 12.which is more sensitive pt100 or pt50 13.why thermocouple are connected in parallel 14.what is lead contact error in RTD,how to avoid 15.what is P,PI,PID,PD controller,why there is no ID controller 16.what is override,split range,sequential,ratio,feedforward,cascade controller 17.why we moved from SR to JK and then JK to master slave JK flipflop,give correct reason 18.how to measure level of a closed container which contains vapour and liquid,remember no vapour gas should be leaked,so ultrasonic and capacitive is not an option,design another method 19.how to design horse race counter including sensors and signal conditioning element 20.what is bevelling
Which are all the commonly used Bordon tubes in the pressure gauges. Do any one use ASTM A 312 tubes for this purpose?
How to calculate P,I&D value in PID controller ?
while am calibrating Drager polytron 2IR flame gas detector occured non zero status.how can i get zero status?
How to erection of DCS Panel at site step by step
what diffrence b/w plc s7200,300,400
please send me some question papers of HPCL aptitude test ?? please send it to bipinb.28@gmail.com ...
What is the basic difference between Modbus and CAN Open Protocols
Hook up resistance decade box to temp.transmitter.
what is the difference between profibus and controlnet networking.
components of control circuit belongs to control valve
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.
How does work A temperature valve or fv control valve in process plz brief me
What are the materials available to prepare individually for competetive exams in Instrumentation field? Plz reply...
Why not come out analog output in ABB EL3020 when display show correct value