how to consider the lap length of a bar in IS code and
specify the code book name and clause& page number?
Answer Posted / jayavijayan k
Lap Splices :
Lap Splices shall not be used for bars larger than 36mm
dia. For larger diameters, bars may be welded. In case
welding is not practicable, lapping of bars larger than
36mm may be permitted, in which case additional spirals
should be provided around the lapped bars.
Lap Length in Tension : lap length including anchorage
value of hooks in flexural tension shall be Ld or 30D
whicever is greater and for direct tension 2Ld or 30D
whichever is greater. The straight length of lap shall not
be less than 200mm, whicever is greater.
*Ld - Development Length
Lap Length in Compression : The lap length in compression
shall be equal to the development length in compression
calculated. But shall not be less than 24D
Bars of Different Diameter : When bars of wo different
diameters are to be spliced, the lap length shall be
calculated on the basis of diameter of the smaller bar.
SOURCE : SP34 Hand Book on Concrete Reinforcing and
Detailing --- Clause 4.4.2 lap splices.
Is This Answer Correct ? | 14 Yes | 4 No |
Post New Answer View All Answers
Will water damage concrete?
i have to give lap joint fo 1Mtr steel of dia12mm,whenever i did mistake i cut less 5cm plz tell me how much i will give lap joint so that length comes 1Mtr
Dear Sir I Mahesh C. Bhamre have already given a Exam for Superintendent Officer / Public relation Officer Exam Dharmday Aaukta held at Nashik on Date 29/08/2010. My seat no was 5040247. and my cell no is 9822677994. and my mail Id is - mahesh.bhamre@rediffmail.com So can you pl send me details of result of respective exams. Thanking you in Anticipation.
We are into industrial flooring (epoxy flooring) business. We buy material from manufacturers.We supply and laying the to companies. In our billing what tax/ taxes to be claimed from companies? Are we applicable for only WCT or any else?
what is the soil bearing capacity for a 5 floor multistorey residential building and which type of soil ? what is plinth beam? in wall load calculation center to center column distance is considered or not/
Test procedure of fly ash bricks as per code ?
if i have to draw bending moment diagram of 4 way continous span then how to create it and how to find reaction?
asubmerged weir is one in which the water level on the down stream side of the weir is just at the crest level below the crest level above the crest level at stamp elevation as water surface on upstream
As per Kandal suggestions, we have implemented rolling starts on 140 (+/- 5) degrees and we kept 3 rollars to complete the rolling before falling 125 degrees and the Aggregate AIV is below 22. But When the DBM bed is being rolled 3rd high viabration, (Before 1 plain & low ,2 high Viabrations), the aggregate is getting sharp edge agg. projections are damaged. As the literature is said that, the VG-30 Grade having better control the temp. susceptibility than Penetration grade. if so we could not get this problem at site. But we are facing on site. let me know.
how to estimate material requirement for an area of house in square feet?
5. Two long boundary walls run parallel to each other at a center to center distance of 1 meter apart. The width and height of the first wall are 0.30 m and 2.5m respectively. While those of the second are respectively 0.18m and 3.5m. Plot the distribution of vertical stress intensity due to walls on a horizontal plane, 1m below ground level. The walls have negligible depth of foundation and are made of brick masonry (y = 19.2 kN/m cu)
The 4 main factors to start a construction project are––
What is thumb rule in quality and quantity estimation of a Residential building??
What sizes of stones chips are used for foundation, column and floor casting. Please answer in detail.
What is the frequency of sampling for the materials of cement,Fine aggregate, Coarse aggregate .and refer which code