Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how inductance related to number of turns in a choke

Answer Posted / jigyesh sharma

yaa i agree with prateek....

inductance is directly proportional to the number of turns
of any coil
n*phi=LI

Is This Answer Correct ?    1 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is maximum power transfer theorem?

1154


what is the difference between changer, converter and transformer?

1614


why HT armoured cable does not glanding

4320


how are reversing the direction of rotation of dc motor

1818


what are the tests comes under the type test, what tests comes under routine tests.

1518


How do I calculate/select Droop CT ratio for various capacity of generators?

3708


what are the necessary basic electrical topics to learn for mechanical engineer to deal practical problems.

2270


What are the difference between CT/PT operated Meter and RRAMR Meter for HT/LT application?

2672


What are high pass filter and low pass filter? and What are the flowmeter ?

2038


How CFL &T5 tube light glows?

2095


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2197


What is a feedback in control system?

1261


How to distinguish whether MCB is DC or AC looking at it physically

2029


HOW MANY TYPES OF FUSE?

2151


WE know that for Inductor X=2pifL,In DC f=0,then X=0 so,V=IX=0;But In the DC excitation of rotor of AC generator,DC motor field coil which coils are inductor so why does not applying DC voltage short the rotor coil of AC generator and field coil of motor?If it would then DC source might be damaged but it is not happened. Why does the strand conductor of Electrical power transmission line make twist?

4435