Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why KBr is used in FTIR SPECTROSCOPY and why is it necessary
to triturate KBr during FTIR analysis?

Answer Posted / nishabd

trituration of KBr is followed to avoid light scattering due to large size of the KBr crystals..

Is This Answer Correct ?    12 Yes 7 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

in which situation ion pair require to use?

744


What is the use of tlc and hplc? And when and where use?

1101


What is the difference between chromatographic purity and related substances?

1296


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1546


In GC calibration,what is the procedure to calibrate the TCD (thermal counductivity detector)suggest ?

3119


How to choose the which salt is suitable for mobilephase

3175


What is mean by PDR?

857


how you establish the LOQ?

720


Which products will produce when acetic anhydride reacts with Ter-butanol, Sec-butanol, Iso butanol, Dimethylamine etc.

2829


AT WHAT CONDITIONS WILL YOU ANALYSE A SAMPLE,WHICH ARE PRESERVED AT OTHER THAN THE AMBIENT CONDITIONS?(ie COLD STORAGE SAMPLES BELOW 20* CENTIGRADE?

2014


How require to perform linearity as per ANVISA? What are the acceptance criteria?

1269


what is the acceptance criteria for enteric coated tablets in 0.1n hcl validation in each parameter?

833


if tech transfer fails whay require to do?

771


Identify problem faced when mass spectroscopy is used with HPLC system ?

1802


WHAT IS THE CRITERIA FOR SELECTION OF TIME OF DISSOLUTION AND THE MEDIUM OF DISSOLUTION?

2524