current cyring capacity of .75sqmm copper cable

Answer Posted / k.prakashchandra

current capacity of copper can be taken as 2.5 A/sq mm but
for generators it is taken as 1.5 A/sq mm.For duration of
less than 4 hours 6A/sq mm

Is This Answer Correct ?    1 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Define unilateral circuit?

709


What is limitedly stable system?

666


What the difference between ac and dc inductor an capacitor

1739


how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.

1748


what would u consider to be the basic purchase order information you would need to proceed with a cable inspection assignment?

1474






1- XC and the RC time constant are both measures of the reaction of C to a change in ____? 2-The power factor is a numerical ratio with a value between 0 and 1 equal to the ______________ of the phase angle. 3-When V and I are out of phase because of reactance, the product of V times I is called ______________ power 4-For _____________ inductors, the branch currents can be added algebraically. 5- The ______________ power in watts can be calculated as I^2R 6-Calculate XL with L = 30mH and f = 1kHz ( I have Xl=2piFL 2*3.141592653*1kHz*30mH =188 ohms Please check) 7-A parallel RL circuit has the values, R = 5kohms, XL = 5kohms. A voltage source of Vt = 10Vrms is connected in parallel to R and L. Determine the total current, It delivered by the voltage source Vt. 8-A series RC circuit has R = 1Mohm and C = 1microF. How long would it take for the capacitor to fully discharge if it is initially fully charged? 9-A circuit has real power = 300W and an apparent power of 500VA. Determine the power factor and phase angle. 10-The time constant for an LR series circuit is T = 0.1s and R = 10ohms. Calculate the inductance L.

2782


Minimum IR value of 1.1 kv grade 3.5c (300, 240,185,150,120,95,70,50,35,25) sqmm Aluminium XLPE cable and 4c (16, 10,6 & 4) sqmm cu arm cable between RY,YB,BR,RN,YN,BN,RE,YE,BE & NE.

2905


what is the reactive power what is the use of it in system

1632


State The Difference Between Generator And Alternator?

677


how to Select Lighting arrester? What r the parameters to be considered for the selection of Lighting arrester ?

1197


What is the need for a controller?

664


what is difference between earthingpits,earthing grid & earthing mess?

2062


who invented active elements? plz give me the complte details of active elements...

1421


What are Contactors? How they works and what its highest rating?

1553


What is safety of Ht panel

1185