Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

1.Whats the use of GNAC(Generator Neutral Accessory
Compartment)

2. why generator or any other system require Neutral
Grounding and not Phase grounding

3. what happens if any one of the phase is grounded.

4. if 15kv is grounded directly what will happen, why it
should not be grounded like that

5. use of of NGTR(Neutral Grounding Transformer and
Resistor) for grounding is helpfull and how

Answer Posted / jax

1. To keep Neutral side CT (Differential CT, NCT, Measuring
CT, Cross current CT, Isolator switch, etc.

2. Phase can be grounded by isolating neutral. But the main
aim of grounding can not be achived. The potential
difference between ground and other two phase (ungrounded
phase) will raise to line voltage.

3. It depends on the type of grounding. For ungrounded
system no faulr current will flow. But the potential
difference between ground and other two phase (ungrounded
phase) will raise to line voltage. For Solidly grounded
system phase to ground fault current will be high. For Low
resitance grounding, phase to ground fault current will be
quiet less. For High resistance grounding, phase to ground
fault current will be very low. (I can explain more about
this).

4. Simple. Phase to fault current will be more.

5. Using NGTR single phase to fault current can be reduced.
Because of this stress on the conductor due to fault
current can be minimized. But the stress on insulator is
increased because of rise in phase to ground potential
during fault.

For any doubt in Electrical you can contact me at
jaxp333@yahoo.co.in

Is This Answer Correct ?    3 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

hi there i am highly enthusiastic about discussing electrical concepts , and hence i wud lyk to invit al do intrested to join me at gtalk and hav a dscussun of the concepts , ad me as a freind . my email id is rakesh.2k99@gmail.com

2149


ANY ONE TELL ME ABOUT generator synchronization panel panel to synchronise 3 gen of 250kva both automatic and manual. 2 gen output vol 415 3ph, 1 gen output vol 400 3ph SEND THE DETAILS DIAGRAM ON THIS EMAIL ADDRESS ayazleo@hotmail.com as soon as possilble best ragrds electrical engineer ayaz mahmood SAUDI TECH

4203


how to compute kAIC?  with formulas...

4293


What is the function of the circuit breaker failure relay?

2426


What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side

1514


Why does an induction generator is preffered as compared to synchronous generator in especially a wind energy power production project?

2177


How to calculate phase to phase difference ?

2308


what happen ehen synchronisation is done at below rated speed

2193


i want bhel placement paper for electrical if anybody having pl send to my id kavitha867@myway.com immediately

2031


in the directional overcurrent and earthfault protection,normally we are setting the angle 45 deg lead for phase fault overcurrent and -45 deg lead for earthfault fro forward direction.but both the fault are operating on the same angle region only.why?how the relay will response?

1884


What test must you do before powering up a circuit that you have been working on?

1910


Is there any question in the name of Static Switch in UPS??

2033


which one is more efficient, torq, power & ecnomy with the same frame size AC motor / DC motor?

2234


What is the role of feedback in a closed loop control system?

1150


1. If 8.35%Z means the percentage impedance of 132kV-line from power company, we will like to reconfirm its base capacity.

2045