how to read AWG n how to convert AWG reading into mm?
Answer Posted / william lobo
American Wire Gauge
(AWG) Diameter
(inches) Diameter
(mm) Cross Sectional Area
(mm2)
0000 0.46 11.68 107.16
000 0.4096 10.40 84.97
00 0.3648 9.27 67.40
0 0.3249 8.25 53.46
1 0.2893 7.35 42.39
2 0.2576 6.54 33.61
3 0.2294 5.83 26.65
4 0.2043 5.19 21.14
5 0.1819 4.62 16.76
6 0.162 4.11 13.29
7 0.1443 3.67 10.55
8 0.1285 3.26 8.36
9 0.1144 2.91 6.63
10 0.1019 2.59 5.26
11 0.0907 2.30 4.17
12 0.0808 2.05 3.31
13 0.072 1.83 2.63
14 0.0641 1.63 2.08
15 0.0571 1.45 1.65
16 0.0508 1.29 1.31
17 0.0453 1.15 1.04
18 0.0403 1.02 0.82
19 0.0359 0.91 0.65
20 0.032 0.81 0.52
21 0.0285 0.72 0.41
22 0.0254 0.65 0.33
23 0.0226 0.57 0.26
24 0.0201 0.51 0.20
25 0.0179 0.45 0.16
26 0.0159 0.40 0.13
| Is This Answer Correct ? | 0 Yes | 3 No |
Post New Answer View All Answers
If only R Phase is connected in 2 pole elcb, n is not connected than it will work or not in ground fault.
what is Different between Bilinear and Unilenier?
what the Microsoft .NET framework is?
What happens if the negative to earth voltage is greater than positive to earth voltage in the battery of substation?
What are your personal skills and abilities for such a Master Course and your possible preparation to undertake this course?
Control wiring of a dol starter for forward and backward
What is the effect of solar radiation on the design of an Isolated Phase Busduct?
Can clean earth cable be considered as low current cable
what do you mean by class PS CT and what are technical details needed for calculating it?
what is meant by twilight switches 7 where its applicable ?
What is main cause of cable's terminal point burned in Lug on high temperature although lug and cable selection is ok as per stantard and also tightness is ok as per situation. so please take in deep and tell correct answer thanku.
Explain what are inter-poles and why they are required in a dc machine.
how we design a pannel to start 10HP motor with the help of star delta starter?
I have a CT meter with ratio 60/5. The meter reading of previous month was 3290.49 and that of current month was 3797.26. How many chargeable units as per normal meter should be my reading.
Explain about how is it working Earth fault'relay and wahts the resistance value of earth bed