Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Is there any option to replace two Genset of capacity 125KVA
with one higher capacity for same office?

Answer Posted / william lobo

Looking at your new feedback; it is possible to install a
new DG set of higher capacity. Since the DG sets are on
rental then its more easy. Just ask the DG set supplier (
the one whose performance is satisfactory) to come over and
surely they will be able to give you free advice on how
best the conversion should be done.
The the electrician or engineer who did the job of
providing necessary switchgear and cabling etc for the
additional loads could be contacted and surely he too would
know what best could be done.
But this may entail higher capacity switchgear, cables etc
to be installed in lieu of the existing set up.
Or like the suggestion to provide one 400A TPN and from
here the same original cables could be used to the existing
lower capacity switchgears.
Also one higher capacity new cable is to be installed from
the new DG set to the 400ATPN.

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

any earth foult trip the relay but in welding time not trip by earth foult

3171


How can I calculate per unit (KWH) fuel (Gas/ Diesel both) consumption 1MW unit?

2108


Haw to check conductivity of budbar

1799


What is Fire Panel ? How it works ?

2065


what is the function of impulse relay

2512


what is the difference between c power and U power acb breaker

6401


Is it required to do earthing in 2nd shop if earthed armoured cable is laid from 1st shop ?

1917


Please explain the following and how these are working with PLC unit 1.I/O Module 2.I/O Device 3.Adaptor Card 4.Ribbon Adaptor 5.RS 485-FC

1594


If not into production, how far did you follow the design and why did not you see it into production?

2168


What will happen to the protection and metering, if the polarity of a single or two PT/PTs in three phase system is reversed? Please provide reference if any.

2181


What should be current in the Primary and secondary side of 1000KVA (11KV Supply)Transformer.?

1047


how to failure indution motor insulation & how to improve heat in motor insulation

1882


3 phase Motor will be given 2 phase after 2 to 5 second we given 3rd phase so Motor Run sum-time in forward or sum time run reverse direction. All time phase sequence is not change. Why motor run in reverse direction? Please Explain........

1949


difference between ac series and parallel circuit

2040


formula for calculation of switchgears(i.e. contactor, fuse, cb, relay etc.), if load current is given?

2194