Explain the working principle of Vacuum circuit breaker and
Air circuit breaker
Answer Posted / siddharth
when fault occure contacts of C.B. open. At that time arc
produce between fixed and moving contact.
C.B. is required to extanguised that arc.
In vaccume C.B. contacts of C.B. placed in highly vacuumed
bottel (i.e there is on any gas or air). For continuty of
arc oxigen is required. There for arc will be vanished.
In air C.B. there is arc spliter to quanche and to
langthand the arc. Due to long length arc resistance
increased and there for flow of current. So that arc
extinguished.
Is This Answer Correct ? | 9 Yes | 6 No |
Post New Answer View All Answers
Wind mill
Suppose a 3 phase, 2 pole, 440V induction motor is driving a flywheel of 600mm diameter, 150kg mass. By using v-belt and pulley, the speed is increased to 4500 RPM. What will be the effect on motor current?
main difference between ac and dc?
IN SINGLE PH TRANSFORMER IF LEKAGE IMPEDANCE DROP IS NEGLECTED ,THE FLUX IN THE MAGNETIC CORE and the lekage flux linking a winding are a)proportional to the applied v to the winding i respectively.
State thevenin’s theorem?
for 100 HP Induction motor service factor is 1.2(SF) we placed a VFD at the motor side load is balance with 0.3 Amp's Phase to Phase but at incoming of VFD load is un-balance with 10 to 20 Amp's what will be cause of load un balance
how we find transformer capacity by ohm
What should be setting for alarm,tripping and cooling fan on for power transformer's oil temp. and winding temp. indicator?
what is the max. acceptable leakage current in 33kv bus bar
how to generator maintenance (A Check, B check,Etc)
give me applications of sequence bridges . (used in 3 phase un balanced systems)
How is efficiency of DG set calculated? At many places I found the efficiency to be mentioned in percentage. But at some other places I found kWH/ litres. I want to know how dimensionless percentage value is arrived at?
What size cable (based on voltage drop) is required to supply a 40 A three phase boiler if the wiring system is 75V single insulated cables installed in non-metallic rigid conduit 56m from the main switchboard? Voltage drop in the consumer's mains is 8V.
for 4 MVA , 33K.V/6.6K.V transformer. secondary side the connected load is 3000H.P. What is the rating of capacitor bank to be insttaled.
one conductor length is L.and i am strech uniformly this conductor and made length is 2L.so resistance of this strech conductor is R=4R..but i want to know about area of stech conductor hows it become a/2..