Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

in power plant which pump is used for feeding the water
a) centrifugal pump or
b) reciprocating pump
and why?

Answer Posted / magesh

All who said as Centrifugal Pump, just cheer up guys.
Centrifugal Pump is always used in Boiler feed pumps.
Because with the usage of centrifugal pump, we can get a
constant pressure with varying flow.
This must be well understood. Because at different load
conditions( if coal input is lesser at some times) then the
feed water input must also be decreased, so centrifugal
pumps are used. With the use of Centrifugal pumps we can
vary the flow. But we can keep the constant pressure.

Is This Answer Correct ?    14 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Name two types of leak detectors and the method of application for each?

3436


how to check quality of steel?

1528


Is there significant affect on the output of modern gas turbines due to low frequency.

2025


why choke is not exactly placed in the middle of the tube light ?

2086


What is the critical temperature of a refrigerant ?

1210


explain how do seamless pipes looks like and when they r used?

3561


I need the complete syllabus and model Question paper for Written exam of JINDAL STEEL AND POWER LTD.,for MECHNAICAL ENGINEERING branch

3245


CAN SOMEONE GIVE ME THE LINE DIAGRAM OF A VAPOUR ABSORPTION SYSTEM (VAM)(AIRCONDITIONING)AND A 600 TON CENTRICUGAL AIRCONDITIONING PLANT.

2149


junior engineeer (railway previous questions)

1915


What is the difference between scavenging and supercharging ?

1469


if the blade height is increased,then how it increases the specific speed of centrifugal pump?

3556


How to calculate motor bearing life - cycle (life time) (SKF bearing) how determine the capacity of refrigeration system? how we use condenser coils, compressor, capillarity,compressor how determine the capacity of refrigeration system? how we use condenser coils, compressor, capillarity,compressor what is rigging

3169


Effect of surface finsh & surface roughness on coefficent of friction in form press tools.

2001


how we calculate the induced air capacity of id fan of a boiler?

2370


Hi! Greetings of the day. Can somebody tell me about as built duct sheet area calculation method. As we know that for this purpose A = (W+H)*2*L. But I have query about multiplication factors for elbows, tappers, offsets etc if there is any. Also refer the papers if available. Please revert. Thanks in advance.

1955