Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

In electrical cables what is U and U0 refers?

Answer Posted / jeffrey tay

U0 is the cable conductor and shield design with metal
cover layer or between the rated power frequency voltage; U
is a cable designed for use between conductors rated
frequency voltage (three-phase line voltage); Um is the
maximum operating voltage of the system; Up is cable
designed for use in each line of core and shield or metal
sleeve Lightning impulse withstand voltage between the
peak.
U0 value is based on cable systems where the single-phase
ground fault occurs when the duration of the permit
determined. In the GB 12706. 1 -91 stipulated in the two
types of cables: Category 1 cables, U0 for 21 kV, for each
single-phase ground fault time is not greater than 1 min of
the system can be used for single-phase ground fault time
of the most length of no more than 8 h, an annual total of
no more than 125 h of the system; Class 2 cable, U0 for 26
kV, for a longer ground fault systems, and cable insulation
performance requirements for high occasions.

Is This Answer Correct ?    5 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how we explain parallel paths armature winding?

2005


how is the testing of an REF relay? what are the test REF circuit having?

2042


What are the properties of a resistor?

1169


Why corona leads to production of Ozone and glow of the color VOILET?

2038


what is the difference between ups & inverter

7342


send me any model test paper of clerical post of state bank of india.......

1898


for 4 MVA , 33K.V/6.6K.V transformer. secondary side the connected load is 3000H.P. What is the rating of capacitor bank to be insttaled.

2633


What is Meter MF if External CT Ratio is 150/1 , PT Ratio is 132/110 Meter CT Ratio is 200/1 & Meter PT Ratio is 110/1

1953


hi frds, i m electrical engineer.can i get cdr for electrical engineer if u have then send me on my mail id its jayesh_ee88@yahoo.com.please help me frds

2242


a 230v transformer with step down ratio 19:1.it has 2000turns on primary and rated 25va calculate max primary current no of secondary turns volts/turn

1612


is it true there's a big difference in using Cummins or Denyo...especially power output or leakage

1981


What is the difference between a verilog task and a verilog function?

1355


what are the ''pitting rings''and how cn they be controlled in a series generator

1893


how many safety really of DG sets.

2275


what is the use of the puls transformer in UPS & how it works???????????

2278