why we use RYB phase sequence? and somewhere we use UVW ?
why?
Answer Posted / ramesh.e
In 3 phase ac systems, as the name depicts, there has to be
3 phases and these 3 phases are named as RYB according to
some international standards. Practically when we see the
three phases we will not be able to distinguish between the
3 phases & so they r coloured Red, Yellow & Blue to help us
identify the required phase.
A RYB transmission line shouldnot be connected to any other
phase sequence like YRB or BRY etc, it has to be connected
with another RYB only otherwise a large circulating current
will flow because of different impedances of different
phases.
| Is This Answer Correct ? | 14 Yes | 14 No |
Post New Answer View All Answers
According to conduit size which size wiring & how many wires can we provide wires in conduit & how can we select conduit size accordingly?
what is formula for calculate thermal overload in new numiricalrelay( not in bimetal relay)?
Why the dc voltage drop during starting of emergency lube oil pump? The Voltage drop from 135kv to 125 kv for one min. before re-establish to 135kv?
hi Is there any possibilities to find out the rotation of a shaft or something else by using electromagnectic waves or by IR rays.If s then can v change the dir., of rotation of the same by remotely?& how? plz dn't any1 say "NO r CAN'T"
In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes
Two bulbs of 100w and 40w respectively connected in series across a 230v supply which bulb will glow bright and why?
following are the questions asked in interviews: 1) Considering the short circuit fault, which switchgear is preferable, SFU OR MCCB? Which operates faster? whicg one is popular in Indian Market and why? 2)Define SCPD. What is type2 coodination? 3)Why the contactor rating is higher for the fuseless selection than for fuse selection? whether the ratinf of SFU or MCCB remains the same in both the cases? 4)If the HP rating is known then can you calculate the ratings of L.V Switchgear(SFU/MCCB, contactor, OLR) without using the selection chart?
Why do we need interlocking in a HT metering or Ring main unit switchgear?
What do you understand by external characteristics of a d.c. Generator?
How many turns are there in primary winding? (In Transformer)
Dear sirs, pls check this 4-20ma to RS485 module datasheet,pls guve me some suggestions. http://www.szsunyuan.com/sy/pro_more.asp?Productid=539 Thanks. E-mail:yunianjiang99@gmail.com
I AM A ELECTRICAL PANEL BOARD DESIGN ENGINEER.IF I GO ANY INTERVIEW ,TECHNICALLY WHAT ARE QUESTIONS I WILL FACE FROM INTERVIEWER?
i want use the cable size 16cx4 core aluminium usege watts 240x2000w this cable size is correct?
What are the disadvantages of thermal power plant?
What is q factor?