Tell me the field calibration procedure step by step with
diagram of temperature transmitter, temperature indicator,
flow indicator, level indicator, control valve,
thermocouple, pressure indicator (digital & analogue).
Answer Posted / satya
temp transmitter :-- 1st of all temp trans mitter is
connected to thermocouple or bed thermocuple or rtd , from
these thing mV IS coming .after that to operate transmitter
we give 24VDC . then temp erature shows in the
transmitter , for calibration we use hart communicater ,
temperature indiacator is calibrated by temperature bath ,
putting the TI to temp bath and get the reading if gauge
is faulty then adjust the spring in diafagram
| Is This Answer Correct ? | 9 Yes | 5 No |
Post New Answer View All Answers
How RAL(Rotary air lock)works in cement industry?
How will you calibrate PID controller? explain with example.
why micro controller 8051/52's clock frequency is internally divide by 12 ?? and why it is further divide by 32 in UART serial communication ??
May I have a brief note above the voltage barriers? Whats is the purpose? Please mail me if you've operational details, mail id: rajkumar.diice@gmail.com
how to calibrate Necleuonic level transmitter.?
can we copy the software from a transmitter using hht(hart 275) ?
How u will setup SPI(2007) on Citrix Server (Thin Client Mode)? Plz Justify?
HI friends.I am Surya a BTech in Electronics and Instrumentation Engineering.I am going to appear Relince Industries Ltd all India writen test very soon. so plz help me by sendind the probable questions about my subject.My mail ID is surya.barik@gmail.com.
I am teja. I am studying Msc(tech) Electronics and Instrumentation (3years course) in Andhra university. But my course is not recognised by UGC and AICTE. Please tell me the job opportunities after this course. And i fineshed PLC course in IGIAT ,Vizag.Also complted my short term coure in SCADA, Seimans WinCC in ATI,Hyd.After Msc can i join Mtech for good job? or phd. How i can get good job in INdustrial Automation Side. Please give replay.Because this is my life matter.
How to calibrate Toxic gas detector?
what is sliding spool valves?
typical loop drawing of a simple feedback control comprising of one transmitter and one control
i want to find out iffco get test paper
How can we test a bently nevda 3500/42M accelerometer monitor card by simulating it with test equipment?. what king od of signal (milli volts or volts or or resistance ) we should feed in the terminals of the card?
while i check zero check for dp flow transmitter some fluctuating came (0 to 458 kg/h) what is the reason?