Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Tell me the field calibration procedure step by step with
diagram of temperature transmitter, temperature indicator,
flow indicator, level indicator, control valve,
thermocouple, pressure indicator (digital & analogue).


Answer Posted / satya

temp transmitter :-- 1st of all temp trans mitter is
connected to thermocouple or bed thermocuple or rtd , from
these thing mV IS coming .after that to operate transmitter
we give 24VDC . then temp erature shows in the
transmitter , for calibration we use hart communicater ,
temperature indiacator is calibrated by temperature bath ,
putting the TI to temp bath and get the reading if gauge
is faulty then adjust the spring in diafagram

Is This Answer Correct ?    9 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What do you know about gail?

2515


There are many type of control cable like pair,core,tried, What are defination each one

2202


A valve in series with an orifice plate (DP transmitter), is aligned for constant pressure in the pipeline, if there is an error dx, How to align it in process.

1401


Differentiate between ultrasonic flowmeter and radar type flow meter

1259


How can test or measure the probe and extension cable to identify if the problem at the probe or cable or at the driver it self? (pleast notify the measuring method)

2644


what is dc moter.

2280


䑰ҕ䔈ҕ䖠ҕ䘰ҕ䛀ҕ䝐ҕ䟐ҕ䢐ҕ䥐ҕŹ

2009


i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....

1511


give me all the details about the interview and which type of question being asked

2264


What is motion balance principle?

1213


What is the cascade control

1482


all types of liquid analyzer principle with drawing?

2011


How does a single acting, spring return ball valve actually work? Does it require continuous air supply? 

2191


What is hp & mp seperator .& what is its working principle ?

2276


I am manjunath having exp in maintenance of chemical plants,know i want to do a design course INTOOLS,after doing design course can we get jobs in design field.sinve i dont have design exp..