Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how to pepare 6.8 pH phosphate buffer

Answer Posted / pavan.rudhrabatla

according to usp
0.2M NaoH perlitre added 112mland 0.2M Kh2po4 250ml per
litre added and mixed very well

Is This Answer Correct ?    27 Yes 8 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how will you do the prep for unstable componds?

2031


Why acetonitrile and water are used as extraction solvent when analysis melamine? I thought they are miscible and won't be able to separate...

1696


in api coa contains only process impurities and in product coa contains degradation impurities?

705


CAN WE DETERMINE THE PEAK PURITY IN GAS CHROMATOGRAPHY ANALYSIS?

1213


How to compare XRD graphs against standard and carry polymorpism study of API's by powder XRD method?

3868


How can we calculate "confidence interval" in analytical method validation? Pl. explain with example.

4280


what is mean by covalidation

786


on the basis of bcs class how to proceed the solubility?

787


Did anybody have method for acetyl cysteine effervescnce tablet

2256


In HPLC calibration, caffeine is used as primary standard for wave length calibration due to caffeine is having dual maxima at 273 & 205 nm and one minima at 245 nm. Any body can give reference of these details from any pharmacopeia (with chapter no.) or any other authentic guideline?

1973


What is mean by PDR?

955


why multimedia dissolution require to do?

836


how to selecet an exact coloumn for an new molecule development by hplc how to select exact salt as buffer for new molecule development by hplc what is the the process to select the mode of saparation of compoundes by hplc what is the use of ph of buffer what is use of buffer,ph,organic phase,ans methods how the molecules get saparated in coloumn,

2607


which batch require to use for analytical method validation?

812


My question about gas chromatography sulfur chemiluminsecence detector. I test unknown sample gas by GC-SCD (calibrated ) and the result of *H2S is 279 PPM , *but when I test the same sample with the GC-TCD (calibrated ) the value of *H2S is 2500 PPM . I'd like to inform you that both GCs are calibrated and have very good operation conditions with stable parameters . the question is if the sample gas with higher H2S over detection limits of SCD detector (1000 ppm). why the result it 279 ppm Best regards

1603