Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why reactive power produce in generator?
why inductive load absorbe reactive power?

Answer Posted / ujjwol

Reactive power is produced by the synchronous generator basically due to the excitation current supplied to it. The VAR it can produce can be controlled by controlling the excitation current with the help of AVR.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is different type of Electrical curve and how it protects the equipment's while up-normal situation?

1809


The transmission does not have options: a)Partition noise b) Flicker noise c) resistance d) Short noise and reason

2433


What is a DC series motor?

1234


This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.

2473


i am completed in B.E(Electrical and Electronics Engineering) with 8 months experience in Quality Control Engineer at Bharathi Industries,Coimbatore.

1882


how to carried out DAR test in 11 KV Alternator ?

2290


what is mean by Digital Logic Meter (DLM)

2373


Explain the experiment on ward leonard method of a speed control on a dc shunt motor with an suitable circuit diagram.

2583


define reflection method?

1936


why do you add the load short circuit impedance when considering short circuit amperage. It seems that you should only consider supply. If you need to consider loads and you don't know what loads are to be added , what would be a good sub-transient reactance rating for the loads?

1789


Why the magneti fields are not passes from southpole to north pole

2110


can we use trip light with bus coupler?

1931


What is servo motor? what is its purpose?

2045


if two transformers are placed parallel & both have fault impedance of 50KA will it increase or decrease show example?

1988


HOW TO CALCULATE HV TEST VOLTAGE FOR ELECTRICAL EQPT.

2212