Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How to calculate Battery back up time for a 400 AH Battery
bank having a load of 20 Amps and charging time required to
fully charge this battery bank?

Answer Posted / kiran

As battery rating given as 400AH, means 20A*20H or 2A*200H
or 40A* 10H like that u can multiply in any proportion
based on the hours.

As the load is given as 20 amps,so it gives battery back
up of 20 hours,which means 20*20=400AH and battery charging
depends on the battery depth and its efficiency to
charge.........

any suggestions or coments regarding to this answer are
welcome......

Is This Answer Correct ?    7 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What happened ,If 3 phase clearance not maintained in 33KV Line,11KV LIne etc?

2351


Explain cmrr?

1118


i have applied for junior engineer 2 c&w for Guwahati RRB please send me last five year question paper

2162


How to calculate per unit impedance of transformer?

2190


what is alluminium arm in ab conductors

1990


Control cables in S's will carry 1000v which is AC R DC? Pls answer meĀ 

2148


I am B.E.electrical engineer having 7 years of experience in Transformer testing upto 315 MVA.I want to khow how I can get the 'Electrical Valuer' License.

2100


how to select the no. of brushes in a lap winding?

2187


explain different losses in a transformer.

1107


What do you mean by turns ratio of instrument transformer?

1090


How do u analyse protection fault when vcb tripping on load

1638


what is differant beetween overload current and phase current?

2325


why most of junction box vendors providing T5/T6 Temp class jb's for T3 area any special reason?

2092


my diploma certificate in my higher education college

1610


75 kw motor take 45 amp in no load delta in star 10 amp but in load it will take 160 amp but IR velue of winding above 500 at 1kw ph to earth and ph to ph. what problem it should be?

3719