Answer Posted / mm
If we are talking about teh motor it self, then check teh
following,
1) while rotaing the shaft, the movement must be free and
there is no abnormal sound. It ensure that bearings are
fitted properly and rotor shaft is aligned.
2) Second check there is any play in the shaft by pushing
it forward backword or up-down. It will ensure that the
bearing housing is ok.
Then your motor is ready for installtion.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
Briefing the effects of ASR and ACR of a double closed-loop speed regulating system.
I had applied for JE in PSEB, Can you pls send me the Question bank for related to my field
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
what is the chemical name and formula of refrigarent R-134a.
how synchronous condenser is used in place of synchronous generator with out negotiating IEEE standards? Can i use 3 generators as synchronous generators and 2 generators as a synchronous condensers in an IEEE 14 bus system with out disturbing the standards?
for a 400kv t/m line with 10 ampere current will corona occur?
What is the role of power pack in substation protection system?
How we can come to know the substation range,without go through any name plate ?
what is the basic need of domestic loads 1- voltage 2- current
Mention what are the types of semi-conductors?
Hi Suppose we have a wye/wye transformer which is grounded at both sides,in this situation, do we have ay ground transformer? in other words, ground transformer can do any thing more (while we have nuetral wire in both sides)? As the last question, what about 3rd harmonic? we have two choices: first using wye/delta transformer + ground transformer and second using wye/wye earthed connection.in the former choice, we dont have 3rd harmoonic at the secondary side but what about Yn/yn conection? do we suffer from 3rd harmonic in the Yn/yn connection?
Explain the operation principle, advantages and disadvantages of the following converters: a) A 12 pulse converter b) A Switch-mode inverter c) A thyristor inverter
What is effect of harmonic current (Draw by VFD) on power system/ electrical Equipments ?
I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?
Suppose a 3 phase, 2 pole, 440V induction motor is driving a flywheel of 600mm diameter, 150kg mass. By using v-belt and pulley, the speed is increased to 4500 RPM. What will be the effect on motor current?