Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why use 4-20mA in the field of instrumentation?

Answer Posted / ajith294

The above answer is correct. we have to need the dead zero,
so we are using 4 to 20 mA instead of 1 to 16 ma

Is This Answer Correct ?    12 Yes 8 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Dear Friends, we are planning to design Power distribution and Fiber optic in the same cabinet.Like Front side Fiber optic and Rear side Power distribution.Is it any possibility of problem occurs like interference etc? Your answer is highly appreciate.

2255


How to calibrate radar type level transmitter for interface level? Total liquid(liq.1 and liq.2), level both the liq individually? For. Both the liquid levels how the signal will go from transmitter to dcs? How to calibrate. Single radar 9:26:55 AM for 2 different liquids in a tank?

2397


what deference between panel earth and systemearth

2378


can we create an interrupt in plc through scada?

2417


why we are using magnet for calibration of gas detector?

2289


Identification of control valve parts.

2108


what is commisioning procedure,2)what is is the main work in commisioning in the field tx to dcs, plz send me detail

2363


i am from instrument branch i want paper patern of mahagenco . any pevious years paper regarding my branch send me please . please.....

2138


I was working on calibrating turbidity transmitters endress+hauser at effluent polishing plant.We calibrated using NTU buffers.What happened is that when we immersed the sensor, everytime we raise and lower the sensor gradually, the reading will vary.my question is that is there any specifications on what is the required distance from the bottom of the container with buffer to the face of the sensor?Is it ok to install the sensor in a medium which has turbulence specially if bubbles are present?

2251


I want to know about DDCMIS in detail ? please explain it. Also give name of reference books in which it is explained in detail in very simple manner.

3909


what should he know if he is an assitent engineer instrumentation in cement industries of experience of 10 - 15 year.

2145


Can anybody tell me which type of question are asked in the interview for the FORMULATION(Pharma) as a instrumentation engineer, & question in building managment system.

2068


need to calculate flow rate with the help of dp range and orifice bore dia and size. range is 0 to 400 inwc and orifice size is 12 inch 150 # rf and bore dia is 7.180 inch. need to calculation for flow rate

1366


How earthing can be checked????

2451


What is the use of GMV in turbine?