why transformer rating in kva and motor rating in kw
Answer Posted / zeyad
when we calculation the power of motor : p= v*i *cos&
but when ------------------------ trans : s= v*i = va
at trans total power maen that : s=p+q
wher: s = total power or apparent power
p= active power( this is the force depent in motion
motor )
q= reactive power( depend in sometime losses)
wehre cos&= real power/apparent
finaly all of above are unit of power
| Is This Answer Correct ? | 0 Yes | 2 No |
Post New Answer View All Answers
What is the tube exial fan?
how to calculate sizing of NGTR (Transformer rating,Loading resistor value and Current rating of resistor) and what is the X/R ratio. Details : 11kV,Capacitance 1.73532 micro farads,40kA for 1sec.
Main advantage of auto transformer over two windings transformer is that A it needs no cooling B it uses only one winding C core losses are reduced D it has simple construction
how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.
what causes contact chatter when there is no demand on the air conditioning unit?
As we know induction squirrel cage motor torque Directly praprortinal to applied voltage in star connection & delta also. If I connect 55KW Motor to DOL starter in load condition does motor withstand the load & what will be the current withdrawn ? motor will not fail ?
Why are iron cores in transformers made laminated?
What is the formula for calculating the Instantaneous Short Circuit & overcurrent for any breaker
Please sent me some previous year question papers of BSNL-JTO telecom and RRB in ELectrical Engineering to varshashahi@yahoo.com
What is the gross weight to copper ratio in slip ring induction motor of 4000 HP,6.6 kv, 372amp, 992 rpm GE motor.
sourse is 66 KV / 350 MVA, transfarmer is 1000 KVA 6.6 / 0.415 kv, iF fault is 28.75 MVA on 0.415 KV Bus then calculat the Transfarmer Impidance
why use phase displacement in transformer.and effect of phase displacement on transformer
what is the minimum requirement gigaohms for the insulation test using 5kv in 300mm xlpe cable
Can you explain about Restricited earth fault protection scheme
Why should we hire you over the others waiting to be interview?