A resistance, inductance & capacitance are connected in
series between points A & B.The voltage drops across the
resistance,inductance&capacitance are found to be
40V,70V&100V respectively. What is the total voltage between
between points A&B (Vab)?
a)210V b)70V c)50V d)230V
Post New Answer View All Answers
can any one provide me a connection wiring diagram for a DG set control panel along with BOM?
generally in LT and MV motors we are using 3.5Coresx16,25,35,50 etc cable for supply.although motors is earthed at two point and having all protection.then why we are using that 1/2 core for earthing the motors.while in HT cable we are using only 3core cable for motor supply.generally lt and mv motors are delta connected and ht motors having star connection.whethere it is having any relation with winding connection( star or delta).all motors i am talking about are dol only.can anybody solve my confusion.thanks...
I'm looking for a softcopy manual set for a Credence ASL- 3000. Anyone know where I can get it?
What is the comparison of PILC and XLPE cable
operation of diesel generator
What is the unit audit? if our Max demand is something and we found much more unit then how to improve our max demand?
Define phase lag and phase lead?
how to calculation increase capacitor,increase power factor for three phase.
1.What is the range of stator resistance of 3-phase induction motor? 2.Two electrically operated vibro motors are foxed in parallel direction in vibrating feeders. what is the direction of both vibro motors?
Define active filter?
How to know the Max. current caring capacity of the cable by its size ?
i am going to correct power factor of 1600kw induction motor,when i calculate capacitance of capacitor it is three time more in star connection than delta. if motor is star connected which connection i shall adopt for capacitors and reason for adopt this connection
Disadventage of cable-gland earthing if any ?
Hi Suppose we have a wye/wye transformer which is grounded at both sides,in this situation, do we have ay ground transformer? in other words, ground transformer can do any thing more (while we have nuetral wire in both sides)? As the last question, what about 3rd harmonic? we have two choices: first using wye/delta transformer + ground transformer and second using wye/wye earthed connection.in the former choice, we dont have 3rd harmoonic at the secondary side but what about Yn/yn conection? do we suffer from 3rd harmonic in the Yn/yn connection?
how to find three phase complex power in per unit and MVA?