Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

in VFD when freq is reduce the voltage will reduceor not if
it will reduced upto ...

Answer Posted / vipul dhruv

basically vfd is a soft starter which is used for induction
machines. there are two methods of control on which a vfd
works... one is the vector control & the other is the scalar
control method. your question does not concern this so no
explanation is required i guess... now the function of the
vfd is to maintain a constant flux in the air gap of the
machine it is used for and that can be achieved only when
the V/HZ ratio of the machine is kept constant.so a ramp is
created in a vfd by the controller which gives a constant
v/hz ratio... and the flux is kept constant... by flux i
mean the magnetic flux.. so as the frequency varies the
voltage has to vary accordingly to keep the ratio constant
which is fed into the controller....the controller is the
heart of the vfd...

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Define corner frequency?

1197


description about dry type transformers

1888


We are preparing another project which involves Waste heat recovery from a 1 MW GE Engine. The Engine in particular gives out flue gas at 487Deg C with a flow rate of 5650 kg/hour and this can be cooled to 180 Deg C. This gives a thermal output of ~ 594 KW that is available for input to VAM via heat exchanger / boiler. Additionally 581 KW will be available from engine jacket water (temperature profile 80/ 80 Deg C and a flow rate of 50m3/hr) Our estimation is that 300 TR of cooling is possible with a suitable VAM machine(s). Please advise what is the most suitable arrangement with maximum TR and min Capital expenditure. plz reply me as early as possible

1981


describe the phenomena of vacuum interruption in C.B

1773


v/f drive basic princeple

2469


How to calibrate or test an LT Air Circuit breaker 440 volts, 35 KA, 800 Amps ?

2595


advantage and disadvantage of team work?

1703


how to interlock 3 nos MCCBs using under voltage coil. please provide me circuit diagram?

2604


what is is the potential diffrence between two phase ?

6404


Why L.T.Cable voltage rating is 1.1kV,where as system voltage is 0.415kV?

2338


what is mean by transition resistance of transformer?

4534


why 1.7Uo for HV cable Hi pot test?IE standard why?

2460


How to run a three phase motor into single phase........

1996


what are the reasons of CT circuit faulty in busbar protection scheme?

1469


1. for eg, capacitor is used for many purposes(it act as filter, oscillator, bypass capacitor, memory storage etc...) 2. Please tell me some example circuits for different uses of capacitor( whenever and whereever and however we used capacitor as a filter, oscillator tuning etc..) 3. similarly for inductor and resistors(it act as what?) and when and how we want to act as like that?, and how we can used these components depends upon our requirments with example circuits and explanation? design to act as these components depends

1829