Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the 415V AC Soft starter? Explain with an example?

Answer Posted / pillay

A soft starter is actually an electronic motor
starter.Instead of using a star delta or a auto transformer
or rotor resistant starter where with the aid of cont actors
and the devices the starting current is reduced to prevent
damage to the motors the machines driven by them or prevent
interruption to the power supply.
The soft starer does the same job but with the advantage of
you being able to preset the starting time and the starting
current consumption.You will be able to determine how much
torque can be given for the starting, but once the starting
is done the soft starter is excluded from the circuit WITH
THE HELP OF A BYPASS CONTACTOR but sometimes maintained just
for monitoring.

Is This Answer Correct ?    5 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.

2130


What is VSCF windelectrical system?

1905


different aspects of voltage stability

2063


Why do we apply both Differential and REF (HV and LV) protection schemes on YNyn configuration of a transformer?

2140


hi there i am highly enthusiastic about discussing electrical concepts , and hence i wud lyk to invit al do intrested to join me at gtalk and hav a dscussun of the concepts , ad me as a freind . my email id is rakesh.2k99@gmail.com

2097


How will A Medium voltage circuit breaker(11 kV voltage level) operate under short circuit fault condition whether It is having short circuit release like Low voltage circuit breaker or relay should be given?

1947


what is a bus post insulator? explain its application in a substation.

12605


solar energy light efficiency & disadvantages?

2117


Transformer how to maintaince a check b check c check d check

2085


what shall be no load voltage of 132/33 kV transformer ? is it 33 kv of 34.5 kV

2190


how to introduce yourself

2034


what is the easiest method of short circuit current calculation ? pls. derive with a mathematical example in real life application.

2431


This is urgent!! What is a Thyristor-based 3-ways selector switch with Zero crossing control? how does it operate and where is it mostly found in a system?

2072


what is the meaning of WYE and DELTA in Electric meter?

3828


Why you want to join non technical field when you are an engineer?

6751