WHAT IS RMU & HOW IT WORK,IT USEFUL FOR HT OT LT POWER
DISTRIBUTION MAUFACTUERE IN INDIA.
Answer Posted / ankur
RMU-Ring Main Unit
It consists of Isolator-Breaker-Isolator configuration.
The RMU is used in the 11 kV HT Power network.
The RMU is using SF6 gas for the arc quenching medium. All
the two isolator and one breaker are in the one chamber
having SF6 gas.
The breaker is having O/C and E/F protection using relays.
The isolator is being used for the operation on ON LOAD due
to the SF6 gas medium.
| Is This Answer Correct ? | 8 Yes | 1 No |
Post New Answer View All Answers
Assuming that a dedicated neutral earthing transformer is provided for each GT generator, when the two generators are running in parallel, has consideration been given that the earth fault current from one generator stator winding be split between the two neutral earthing transformers? If so, what adverse impact will this have on the operation of the 59N and 27TN devices?
While testing a ZCT what parameters have to check or measure?
How would your past experience translate into success in this job?
define reflection method?
In case of salient pole alternator when number of poles are 4 or more than 4 it helps the flux wave to be sinusoid as air gap length is increased from center to tip , but if the number of poles are 2 how does the flux wave is sinusoidal?
how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.
in HT service 3ph 4 wire service Y-phase voltage shows zero . whether it is meter fault? or what be the reason ? if y-ph voltage zero ,can current is recorded? reasons for failure?
what is the role of energy meter in distribution system ?
A 3-PHASE TRANSFORMER IS USED TO STEP-DOWN THE VOLTAGE OF A 3-PHASE, 11KV FEEDER LINE. PER-PHASE TURNS RATIO IS 12.FOR A PRIMARY LINE CURRENT OF 20A, CALCULATE THE SECOUNDRY LINE VOLTAGE, LINE CURRENT AND OUTPUT KVA FOR FOLLOWING.A)STAR- DELTA.B)DELTA-DELTA.
Write a note on materials used as a fuse element.
how u select control transformer for a mccb panels or any panels?for expample we hav 440 volts maim supply and control volts is 230v?
what is the relation between reactive power and power factor for the what is the limit of reactive power and power factor
What is meant by time harmonics and space harmonics?
What does the kvar means?
how can we design robots