Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

When measuring the Insulation resistance of a motor winding
(winding to earth) using a megger meter, Applied
voltage(1000V) was automatically reduced to 500V. and the
measured insulation resistance values are also very low (in
Kohm range) Can anyone give me a reason???

Answer Posted / dum

Thanx Sridhar.. ur answer is clear. But i want to know why the applied voltage is automatically reduced as i have mentioned in my question?? is there any theoretical explanation for that??

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How do i carry out or know the vector group of a Dyn1 and Dyn5 transformer

2048


Discuss about gear cutting machines.

1219


An ELHNC 80amp 240v 30mA RCD is tripping periodically, every 30 - 180 seconds is it safe to disconnect the protection circuit?

2151


Can you used moeller lzm1 mccb in a dc system with 125vdc and 20ka short circuit current , beside is it have 24 or 48 volt shunt ? Beside how long current can through from An MCB shunt contacts? (like Z7-AS 24 V)?

2089


Why neutral cable carry current.

1974


pls tel me the electric train traction motors name plate details like rpm,torue,voltage,amps,watts..ect..

2056


Define step response?

1182


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

2034


how many joints are allowed in underground HT cable of 1 KM

1878


our industries ht line so power fluctation(once drop of power please rectify causes

2257


what is cascade speed control device?and how this device control the speed of motors?

2158


1.what is difference in maintain Hz again Hz in USA ? 2.how to calculate the battery AH? 3.why are yearly maintained in transformer how many tests in required?

2779


How shall i select the value of capacitor or inductor in a system?

1900


Mention the disadvantages of low power factor? How can it be improved?

1151


WHAT IS THE TECHNICAL SPECIFICATION OF C CURVE & D CURVE LEGRAND MAKE MCB

2664