Answer Posted / deepak
By earth resistance tester that consist of 2 electrodes
along with its leads.Connect one lead from earthpit to
tester & burry 2 electrodes in earth & connect there
respective lead with tester & then check the earth R. It
should be from 0 to 1 Ohm.
| Is This Answer Correct ? | 12 Yes | 3 No |
Post New Answer View All Answers
How to derive detailed design of Suitable bus Bar for 100A for 6.6KV?
If we are given a 10 amp cable type and asked to calculate the number of cores used and the thickness of the cable, how do we do it?? please help...urgent!! i hope the question is clear enough!!
what is the relation between reactive power and power factor for the what is the limit of reactive power and power factor
Readings of ER300P Trivector meter
what is the difference between online & offline caliberation of KWH meters. Can Digital meters be caliberated
what is the difference between torque induced and torque load?compare them with respect to dc motor?
Is electro plating what type of load whether resistive, inductive or capacitive loads
What is the breaking capacity of transformer and how can we calculate the breaking capacity of tranformer
why ht cable end termination don't have a gland?
What is the Resposiblity of Electrical Utility Engineer
operation of diesel generator
How to Calculate The Neutral Earth flat design calculation for the Synchronised generator (Gen 1-650Kva, Gen 2-725Kva
How to know vacuum in vacuum cylinder of breaker in working condition
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
what happen if the load connected to the induction motor is taken away? the same question for synchoronous generator in synch i think that the the exitation voltage will appear on the terminal only if so plz answer me