Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

difference between IR& FTIR

Answer Posted / saidi reddy

FTIR Instrumetn is having interoferrometer is correct but
the function of this interoferrometer is it covers only mid
IR range only.
In IR it covers all infrared ranges from far to near IR
ranges.

Is This Answer Correct ?    17 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why perchloric acid used for potentiometric titration

2678


As per ICH related substances stability trend limit from initial to shelf life

3247


If inhouse hplc related substance method is completly diffrent from Usp for finished proďuct with diffrent impurities then how require to prove method equivalecy?

771


how you establish the LOQ?

788


How to determine the EDTA content by potentiometry titration in Ceftriaxine sodium

2544


can we use the same detector in HPLC as well GC and what could be the differences we can find in the final chromato graph in any aspects?

2179


which batch require to use for analytical method validation?

802


How do we quantify crystaline and amarpous forms by using (NMR, XRD)spectroscopic techniques? Which any others instruments are useful for this quantification? explain

2388


what is lod and loq ?,why use k2cr2o7 , kcl h2so4 in uv calibration ?,why use benzophenone & caffene acetone in hplc calibration ?,what is leading peak in hplc ?why we do the calibration of limit of stry light in hplc & uv ?

3666


Why dissolution test is not performed in all of the products

2535


Why only hydroxy naphthol blue indicator is used for standardisation of 0.05M EDTA solution instead of solochrome Black T or Euriochrome Black T indicator which is used for all sample analysis with 0.05M EDTA solution?

2719


Loss of linearity in tkn analysis, possible reasons?

1315


how to selecet an exact coloumn for an new molecule development by hplc how to select exact salt as buffer for new molecule development by hplc what is the the process to select the mode of saparation of compoundes by hplc what is the use of ph of buffer what is use of buffer,ph,organic phase,ans methods how the molecules get saparated in coloumn,

2599


What is dose dumping? why require to do?

947


Describe your field experience sample type collected,sample techniques,field measurements taken and equipment used?

2695