Answer Posted / anupam a h
CT is basically a step up transformer with primary
connected in series with the load circuit,so thet we can get
a low value of current in the secondary which is
instrumentally measurable.but consequently a high voltage
will be developed in the secondary if sec is left open.to
prevent the high voltage the sec of CT is shirted
Is This Answer Correct ? | 16 Yes | 24 No |
Post New Answer View All Answers
Give atleast 20 alternating current apparatus and devices.
I want to know Electrical Circuit?
we can run 2phase as 3phase .what will be the differnce with respect to phase angle, power, current between the two modes
why we permissive overreach in distance protection.where it is applicable to use in long r short lines
when we design electrical schemes of 11/.415kv distribution..wen and were should we show the relays??what is the function of it?for example..we place EFR Relay CT between transformer neutral link and transformer earth.Like this what are the other type of relays we should use?why?where?Explain please..Thank you
What is vacuum circuit breaker.define with cause and where be use it device?
hwat type of motor is used in thermal gas turbine hydro nuclear power plants and why
how to find ratio of CT & PT in 66/11kv 12 mva supply system ? explain with calculation.
I need HT sphere gap calibration table. Can any body help me.
star delta starter contorl circuit... drawing..
What will happen if we introduce negative feedback to a control system that uses a positive feedback?
What is quadrantal symmetry?
According to IEC60034-14, When the vibration monitoring system required for motor Bearing. above which KW, it is required? and for what type of bearing the vibration probe is provided.
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
Explain the role of a car driver as one of a feedback mechanism.