why we use RYB phase sequence? and somewhere we use UVW ?
why?
Answer Posted / roysayan01
In 3 phase ac systems, as the name depicts, there has to be
3 phases and these 3 phases are named as RYB according to
some international standards. Practically when we see the
three phases we will not be able to distinguish between the
3 phases & so they r coloured Red, Yellow & Blue to help us
identify the required phase.
A RYB transmission line shouldnot be connected to any other
phase sequence like YRB or BRY etc, it has to be connected
with another RYB only otherwise a large circulating current
will flow because of different impedances of different phases.
| Is This Answer Correct ? | 43 Yes | 33 No |
Post New Answer View All Answers
Hi I'm doing my MBA(3rd semester).I applied for the post of ET conducted by BHEL the last year.I cleared the written and lost in personal interview.Again I wrote the exam this time and cleared the written n yet to take the personal interview.Shall I disclose in the interview about my studies.What shall i say if they ask about my change from studies to job
WHAT IS DEAD END IN PROTECTION?
importance of reactive power management
How does a tertiary winding filter harmonic(espcially 3rd one) from entering into load system?
Dear all i want to know SEWA Electrical Supervisor Licence test Previous Year Questions ? If any body know please send to me zohairaukllah@yahoo.com
I have c license but I don't know eligibility of Max Kilo Volts under the electrical licensing board.
Basic motor transformer generator
When we have earthing mesh or underground earthing network in industrial plants, weather we have NT-S or NT-C-S kind of earthing system, so eventually weather we must use 4 or 5 wire in 400 volt level (For example 3×150+70 mm2 or 5×150 mm2) in this connection I would like to know exactly the paragraph of IEC or IEEE number
in science exhibition how lamp can blink when you clap near the lamp ? thank you
state the working of discharge lamp?
How to calculate phase to phase difference ?
What is the drawback of class b amplifier? How is this minimized?
neutral earth resistance testing is it possible for transformer while in load condition
Can we use both Electrical & mechanical interlock between tow breakers? if yes how, please explain
How to choose the vector group for the step up and step down transformers??? Tell me the which vector group is suitable for step up and step down transformers and whats the reason to choose and whats the benefits???