Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the Difference Between MCCB & ACB & VCB

Answer Posted / jigs

MCCB-moulded case circuit breaker; ACB-Air circuit
breaker;VCB-vacuum circuit breaker.
Well they all the diff kind of design. Their operating
range is also different.

Is This Answer Correct ?    9 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the use of oil in transformers?

1038


do any one help me to get "C" license,, i have doubts ,,, if mediators ter pls call me,, my no is 8056640042

1381


write a program that prints prime numbers from 1-20 in digonal form

1954


1. How many types of mangers? 2.How many types of capacitors? 3.pls tell me normally types alternator problems?

2255


We have two parts in generator, electrical & mechanical. how it works?

1898


what is meant by impedance & transient protection?

2065


HOW TO SET THE EARTH FAULT SETTINGS IN ACB????????????

2121


how many joint can done in HT line and what is life of the joint

2170


How will be the single line diagram of series trip HT breaker? how it works?

2545


Which capacitor is preferred for high voltage and frequency?

1008


Application Comparison between 22KV (UE)and 33KV (E) system. Are we allowed to use 33KV (E) cable in lieu of 22KV (UE) cable. What are the technical disadvantages.

2772


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2094


How a capacitor discharge weld power supply works? what is the use of a pulse transformer?

2018


why magnet has north and south poles only why not east and west and why we are considering as north and south poles? why cant we consider as east and west?

1982


WHAT IS MEANT BY SHEATH VOLTAGE IN 132Kv cable?

2228