voltage of a ckt is measured by volt meter having an input
impedence camparable with the out put impedance of the ckt
Eror caused is
1. Gross Error
2. Errors due to lloading effect
Answer Posted / sandeep
though it seems errors is due to loading effect, it can be
Gross error also a it is misuse of the instrument. please
justify..
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
HOW WE KNOW IN PHYSICALLY THE CONTACT SURFACE OF A VACUUM INTERRUPTER IS GOOD OR GOING TO DAMAGE IN A VCB AFTER ABOVE 500 TIMES OPERATED.
what is the write prosidure of stringing of 8meter pcc pole.
I have c license but I don't know eligibility of Max Kilo Volts under the electrical licensing board.
we have two generators different capacity on 15 MW and other 6MW at 11 KV , 15 MW gen. bus short level current 40KA,and 6MW short level current 25KA,, length of cable 100MTR between 6 MW from 15MW gen. for bus coupling . kindly tell any one can we use both NGR OR one NGR from any GEN. BOTH NGR has diff. rating. Tariq pakistan
salam,hi, i need to know what the spesification of 300amp msb...
What is the difference between type1 and type2 relay protection co-ordination for motor feeders
Give me the calculation steps to design an electromagnet to be work in 230V 50 Hz AC Supply. Also give force that is created by that electromagnet when it gets energized.
what is the function of choke in the flourcent tube lights and why the colour is in white mostly in flourcent tube lights
Can we check ELCB constantly from R1 to R8 phase in 1 no DB?
What is the real function of reverse power relay in generator panel while syncronising?
What will happen if a dc source is given to a tubelight. Will it work or wont it work....
hi I have done 3 yrs diploma in electrical engg after 10+2. I have 16 years of work experience into design proposals sales and engg application development in LV/MV swithcgear and sub station automation field. I want to apply for immigration to new zealand but I am not sure whether I qualify or not since I dont have a degree. Can anyone advice? Thanks Riz
what is the difference between online & offline caliberation of KWH meters. Can Digital meters be caliberated
I'm generating a pulse of 3V with frequency 80Hz (12.5ms time period) and pulse duration 0.125ms and feeding it to a transformer since i want the pulse to get amplified around 60V. At the output amplification s happening but the pulse is changed to a spike, can you tell me what could be the reason? (an ordinary transformer 220V-12V stepdown transformer is reverse connected ie. now it is 12V-220V stepup and voltage amplification happens)
How to calculate or formula to calculate rhe power in 2 phase system ??