Why the size of transformer decreases if we increases the
frequency?
Answer Posted / www.pooneetkashyap.blogspot.co
from emf equation of X'mer
E=4.44fNAB (http://en.wikipedia.org/wiki/Transformer)
where E=voltage
f=frequency
A=Area
N=number of turns
B=magnetic flux density
in general we can say
A=E/(4.44fNB)
for constant value of E,N,B
if we increase F,then Area of core will decreases means size
of transformer will reduce.
| Is This Answer Correct ? | 123 Yes | 9 No |
Post New Answer View All Answers
what happens in the short circuited secondary transformer,if the resistance of the short circuit is increased gradually?
Initially, when the input is not equal to the output — what type of response is this?
Dear all, I'm manikandan I have done by DIPLOMA EEE from 2011 , I have 5 years of experience from Power plant instrumentation field , which one field is give long life & which one field is best ,I confused a lot and also I'm studying AMIE, can I choose which department from Section B examination? pls tell me
How to do cable sizing calculation for 750 A Neutral Earthing resistor for 33kv. the 33kv cable going to swbd. is 630mm2 3 runs.
What is the power requirement of tamil nadu for one month?
What are the applications of different multistage amplifiers?Plz also write advantages of these amplifiers? Thaaaaaaaaanx
In AC if the direction of current keeps reversing every half cycle, how does it propogate through the transmission lines?
why star point of HT motor not earthed?
Dear all i want to know SEWA Electrical Supervisor Licence test Previous Year Questions ? If any body know please send to me zohairaukllah@yahoo.com
Define resonant frequency?
what is difference between earthingpits,earthing grid & earthing mess?
what is the write prosidure of stringing of 8meter pcc pole.
what is difference between window type and wound type transformers?where we will use window type and wound type transformers?
How to calculate the multiplying factor for energy meter with ct ratio given
What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side