Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

define optical temperature detector

Answer Posted / hassanelect

Fiber-Optic Thermometers:
These instruments enable near-infrared and visible radiation
to be transmitted around corners and away from hot,
hazardous environments to locations more suitable for the
electronics associated with contemporary radiation
thermometers. Fiber optics also makes possible measurements
in regions where access is restricted to larger instruments
and where large electric or radio frequency fields would
seriously affect an ordinary sensor. Conceptually, a
fiber-optic system differs from an ordinary IR thermometer
by the addition of a fiber-optic light guide, with or
without a lens. The optics of the light guide defines the
field of view of the instrument, while the optical
transmission properties of the fiber-optic elements form an
integral part of the thermometer spectral response.

Reference:
Process. Industrial Instrumentation & Control Handbook

Is This Answer Correct ?    1 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why is not useing in boiler skin thermocople

5282


draw shematic diagram of c/v positioner(smart type)?

2226


what is 24vdc live and dry supply

2273


A length of steel pipe is used to carry sea water to a desalination plant. An adequate corrosion allowance must be specified and indicated in the piping specification, which affects the _________________________ of the pipe

2255


can anyone can let me know in Eurotron Micro cal 2+ calibrator in milli amps source mode we are not able to get 20 milli amps output it only produces 1.52 milli amps out, but display shows increase in milli amps , and err6 displays, let me know how to remove the err 6.

2269


How is PH sensor works ?

1973


Exothermic reaction./ endothermic reaction

2041


i want to know the interview format fot gail, instrumentation. pls answer me in habib.sami1003@gmail.com

3181


WHY THE DEGREE OF VALVE PLUG AND VALVE SEAT IS SLIGTLY DIFFERENT I CONTROL VALVE TRIM DESIGN

1993


how can be calibrate flow indication transmitter (rosemount) it shows excess milli amps nearly about 24 ma on full scale, but its scale was set on 20ma on full scale..???how can be simiulate..???

2408


What happen if we install my pressure transmitter below the elevation of pipe in natural gas service?

1065


What are the type of bonnets in the control valves?

1871


what is the usage of QDV & VOLUME BOOSTER

2319


what is surge and how is it prevented, what is the purpose of bypass valve across AS valve.

1980


 why Fahrenheit unit of moistur analyzer transmitter

2240