What is the differance between a converter duty transformer
and normal power transformer?

Answer Posted / veer1981

Converter duty transformers are used as set up transformer
from generator to line voltage. Converter duty transformers
have range up to 10 MVA with the voltage capacity of up to
33 KV. Converter transformers and heavy duty transformers
have very durable and hassle free to be used by desired
clients. It comes with an automatic on/off cooling option.
We offer these converter duty transformers and heavy duty
transformers at a competitive price.
One of the main differences from other types of converter
transformers is that the load currents contain higher
harmonics due to the distorted waveform. The converter to
the transformer causes the distorted current waveform. This
has to be considered current leads to higher losses &
temperatures in the transformer. Network regulations also
require reduction of harmonic distortion.

Is This Answer Correct ?    8 Yes 21 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why it need to form a capcitor when it not been in use from three or two year. Plz describe it technically.

1472


xfhnchncv?

1412


For a three phase induction motor, what will be the effect on motor if the neutral of the system is shifted to say 20 deg.?

1406


can indirect loading be called as phantom loading?

1565


i applied for the ap transco please forward the freqventley asked QA

1550






why transformer tank is in rectangular shape what happen when it is in step shape

960


what is invertor supply and raw powersupply

1534


is it possible to turn on the single phase star delta on delay timer using 24 v dc ?

1477


What is the difference between the relay and the circuit breaker?

616


Do inductive loads have distorted current waveforms ?

1399


how do i work out the Amps of a incommer if i am running 1 37 KW motor and a 0,75 KW motor and some solinoids

1428


Consider three heater bank connected in 3 phase star with neutral.Each heater bank connected in each phase.So each phase get 230 volts supply.my question is,during balance condition, current flow in neutral or Not

1205


what is the formula for calculating the phase clerance between two phases and phase to earth how to calculate the cable for a motor

1481


how can motor both beasrings insulation resistance can be check?

1557


Is it required to lay 2 runs of GI wires along with armoured cables from one power DB to another Power DB?

1482