Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

mix proportion of M20 AND what are different grades below it

Answer Posted / vishu

(these Grades can also be designed in RMC as "Design
Mix")

M20 1:1.5:3
M15 1:2:4
M10 1:3:6
M7.5 1:4:8
M5 1:5:10

Is This Answer Correct ?    22 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how much percent are used 20mm,10mm?

1952


can i get hindi version of is codes based on civil engineering?

4361


If specific gravity of cement is less than 3.15 what is the cause?

2307


HOW TO CLACULATE CEMENT AND SAND CONSUMPTION FOR THE STAIRCASE KOTA FLOORING IN THE RATIO OF 1:4 50 MM THICKNESS

4667


1:4:8 pcc calculation 591 cu.ft

2291


Can any body help me out by telling hoe swelling pressure test of soil is carried out ? some body told me the procedure & formula (change in length /116.3*100%) but still i am confused ? pls help.

1966


04. a. Slenderness ratio…………… 1 b. If the height of a stage is 15-0 & dia. of the prop is 5, the slenderness ratio is….… 1 c. If the height of a stage is 10-0 & dia of prop is 3, the number of bracing will be…… 1

2039


What is the Hardness of M-40 grade concrete, general and theoratical

2117


how to calculate mivan shuttering matrial

1571


How we can calculate the cement, sand,bricks , water , quintity in 1:6 Ratio 1 cubic metre b/w and 1:4 Ratio in 1 Squre metre b/w????

2028


What is .Dwg?

1290


column at edge of a framed structure is uniaxial or biaxial. and is an interior column is biaxial

3929


How good are the Weinerberger Porotherm bricks that are being used in construction in Chennai, India. Its being used in non load bearing walls and has a compressive strength greater that 35 kg/cm^2 and a density of approx.694 - 783 kg/m3.

2852


what is civil all interview questions

2774


For removal of formwork of simply supported slab / beam from where to start the deshuttering? ( Max Bending moment of the simply supported beam is in the center hence is it required to start from the supports?)

2049