heat can flow from a body at low temperature to a body at
higher temperature only when ........ is supplied from an
external source

A). Voltage B). Current C). work D). Mass

Answer Posted / parth

the correct answer would be (d) mass.
see, when you put a hot iron rod in water, it will transfer
its heat to the water and cool down, without providing any
voltage, current or doing any work on it. the only thing
required is a sufficient amount of water. so sufficient
Mass of water is required.

Is This Answer Correct ?    3 Yes 9 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What happens when ac supply is given as excitation voltage instead of dc supply

3147


The knee point of a current transformer is normally unique and known.So why in the nameplate of a CT they put the minimum value like this Vk> 400v.

938


how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?

1409


What is the use of iron core in a transformer?

649


what will happen if OLR CT in all phases are short circuted

1689






i want to learn control schedule for 11kv panel? can any one send the detailed control schedule?

1924


What are the types of the glands and difference between single and double compression type of cable Glands.

1626


I would like to know that the fault curretn at base load and at 10% generation will be same? Fault level of BUS remain same with different generation?

1397


A TRANSFORMER 440/400V,DELTA/STAR CONNECTED.THE NEUTRAL CONNECTED WITH GROUND CABLE THAT IS DIRECTLY CONNECTED TO THE PANEL,FROM PANEL IT IS CONNECTED EARTH PIT.IS IT RIGHT? IF IT IS RIGHT LEAKAGE CURRENT AFFECTED.SECONDATY IS PROTECTED WITH EARTH LEAKAGE RELAY.

1717


what is mean by parallel operation of permanent magnet generators

1480


why we use the 100% and 95% stator earth fault protection for the synchronus generator ?

1843


how we arrange the hv side with delta connection in case 33/11kv of transformer.

1550


can we synchronize star system generators with delta system transmission line ? and how ?

2314


What are the different circuits in thermal power plant?

724


L.A. (Lightening Arrester) is located at a place from where transmission line enters the transmitting substation. So L.A. (Lightening Arrester) is the first equipments which has to encounter with lightening, high voltage surges and switching surges. It has to absorb energy of lightening, high voltage surges, and switching surges. L.A. (Lightening Arrester) is made up of layers of semiconductors. If these layers can not tolerate energy released by lightening, high voltage surges, and switching surges the L.A. (Lightening Arrester) blasts.