Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what do you mean by puncturing of insulator by ice -coating?

Answer Posted / raghavendran

I am not sure but,this could be the reason, the Electrical
field intensity producing corona on contaminated areas,
water droplets, icicles, corona rings, ... This corona
activity then contributes nitric acid to form a chemical
soup to change the bonding cements and to create carbon
tracks, along with ozone and ultraviolet light to change the
properties of NCI insulator coverings. Other detrimental
effects include water on the surface or sub-surface freezing
and expanding when thawing, as a liquid penetrating into a
material and then a sudden temperature change causes change
of state to a gas and rapid expansion causing fracture or
rupture of the material.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

for 750 kw LT load what will be the ht kva

1656


Explain about 3 phase motor fault current calculation with examples?

2953


How does the phase sequence controller works, how it identifies the phases? confirm working principle

2112


state types of reflectors in illumination engg. ???????

1943


can the measured percentage error during calibration of single phase energy meter be negative?

2418


what is the min and max ohmic resistance for the earthing rod installed for lighting poles for street light network

3816


During Testing of Maintenance Free Earthing, How deep should be the Spikes of Earth Test Meter should be inserted in the soil(one spike is 15 Meter & Other spike is 30 Mtrs away from the Main Earth Electrode. Because, recently, we observed that when spike is inserted 3-4 Inch in the earth- results are better, If spike is inserted 1 feet deep than results are increasing.

1953


How many double suspension hardware fittings are required on a double circuit transmission tower?

2114


State nyquist stability criterion.

1184


redundant connection in contactor?

2509


What the main causes of transient interruptions on Over-Head Distribution Lines?

2156


what are the installation procedure of high voltage power transformer,CT,CB&PT?

2078


What is the name of transformers oil filteration equipment?

2093


what is the difference between an alternator and a synchronous motor

2029


What is domestic transformer? Draw the connection of domestic transformer.

2325