Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How check electrical motor winding.

Answer Posted / anil bhatia

1. Check the resistance of all windings. In case of three
phase motors resistance of all windings should be same.

2. Check the insulation resistance with megger. It should be
near about 1M-Ohm.

i am agrred by the statment given by friend but also in
some cases both above1 and 2 we find ok and problom we
find in iduction reactance which only can be measured by
motor checker .

Is This Answer Correct ?    4 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

In motors how many types of cooling systems were used?

2063


What is s-domain and its significance?

1168


1 Ton is equal to how many watts?

1093


what is package substation.how many types they have

2101


What is the general power factor & min. power rating of TV,LCD type TV, CRt type TV, Scanner, printer?

2052


Under wat condition statcom operates as an inductor for the transmission line?

1928


Briefly describe your ideal job?

2964


May I know how much values to be set for earth fault, over current and short circuit values at 11kv side? I have 11kv van 1250amps rating. Present it's taking load 80amps?

1489


How do I calculate a WTI CT ofa 1250kVA 6600/400V transformer

1742


What is meant by stator?

1199


WHAT IS THE WORKING PRINCIPLE OF A GENERATER.how is a GTG (Gas TURBANE Generater) working.plz explane

2515


234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,

2013


I have 1500/1A CT If i connect this CT in 6.6KV bus bar means what will be the voltage present in CT?

1994


how u select control transformer for a mccb panels or any panels?for expample we hav 440 volts maim supply and control volts is 230v?

2163


What is the difference between DOL starter and star delta starter

1125