Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is mean by vector group? For what purposes we doing
vector group test in transformers?

Answer Posted / satya dev

In the 3 phase AC systems all the phases are having Phase
displacement called electrical Angle.In the case of
transformers the windings are connnected in special Faison
called Vector group. DY11, DYn11 are the vector gruops
which are generally used in India.Testing of vector group
is only to test the electrical of Connected Phases in the
Transformers.

Is This Answer Correct ?    4 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Does outdoor isolator loose connection cause short circuit current in that circuit? if yes then how ??

1751


Practical condition in 400KV Sub station:- Breaker(open) , isolator(open), Earthing (close) at both end e.g A & B. Now Open A Stn Earthing than Open B stn Earthing (Which have a 50MVA reactor) , AND suddenly show R,Y,B phase 704KV,573KV,118KV respectively. Que is without closing of breaker how it is possible.???? My Whats app No:07621840498 for Further Discussion. Pls experts suggest.

2144


how to prepare the technical test

2138


can i connect wavetrap in 2 different phase in EHV line?

1918


sir please send me iocl written test paper in my e-mail account. i'll be obliged to you........ thank u roshan

2267


can we find the inductance of a induction motor?

2048


Differentiate between kirchhoff’s first law and kirchhoff’s second law?

1113


Draw torque - speed curve and load curve of induction motor? mark operating point ?

2113


PLZ sent the previous year question paper for GET in NHPC on my EMail id ppshanker@gmail.com

5491


How phase to phase voltage comes 440V.

2166


i am going to attaned the engineer (disign)iterview at HAL please give me duid line

2328


I have a drawing of a wound rotor induction motor for a crane. This crane motor has 5 forward speeds & 5 reverse speed implemented of course with different amount of resistance for each speed setting selected. What has got me scratching around is the fact that 8 of the 10 speed selections switch in uneven (unbalanced) amounts of resistances on each of the 3 connections to the motor's rotor.Can this be possible? I would have assumed this would produce unbalanced rotor currents and therefore vibration in the motor. I would greatly appreciate anyone's comments on this. Many thanks, Confused.

1908


Convert a star connected network into a delta connected network.

1166


Importance of fault current in power transformers and how to monitor the same? How is it different from winding temperature?

1890


Define active and passive network?

1192