Answer Posted / abhishek singh
NEUTRAL IS NECCESARY BECAUSE NTRL ACTS OR PROVIDES THE
OPPOSITE PATH TO THE CURRENT.CURRENT HAS ITS OPPOSITE PATH
IN ANY CKT.SO NTRL FULLFILL THAT OPPOSITE PATH.SO IT IS
NESSARY WITHOUT IT THERE IS A ERROR OF OVER VOLTAGE IN
ELECTRICAL CKT.
Is This Answer Correct ? | 1 Yes | 2 No |
Post New Answer View All Answers
how can i reduce sparking without stepdowning the voltage
how to calculate regulation constants for over head lines? and what are the regulation constant for raccoon conductor at different voltage level and different P.F?
A powerplant has 8 gensets operating in grid parallel mode. In one genset sometimes there is pf variation and kvar variation. The plant operates in pf mode. When this variation is observed the load is stable, voltage is also stable, freq and genset speed is also stable. How will you check the functioning of pf card. What shall be the ideal output vdc of the pfc, from there it is input to AVR?
Explain what is electric traction?
what is smartµ grid technology?under coal gassification?
a starter used for squirrel cage induction motor?
i have completed deee and i've (June2012-feb 2015 experience in electrical maintenance in pvt ltd company.company having HT & LT electrical power.how to apply electrical C-license ,NOW I was resigned my job,what are requirements of applying for c-license
Differentiate between digital phase converter and ordinary phase converter.
what is charger supervision and control supervision?
what are the different kind of cables used for transmissions?
Hi guys! Plz help me to answer the following questions. 1. What are the types of transmission line energy losses? 2. Why are the VLF are used some types of services? 3. What frequencies are used for reliable beyond the horizon terrestrial communication without repeaters? 4. To permit selection of 1 out 16 equi-probable, what is the number of bitis required? 5. What is the most common modulation used for telegraphy? 6. What is the multiplexing is used to increase the capacity of the optic fiber? Thanks
What is the tests required for a 132 kV, 400 kV , 765 kV for a Circuit Breaker and Power Transformer before commissioning ?
We have 750KVA DG set, we want to introduce REF relay with 1250/1A,CL PS,Current transformers.The lead distance of 2.5mm copper flexible cable from CT to relay is around 5mtrs.We would like to know the knee point votage(VK) & IM calculion for CT's
what is the soft starter principle? how is connection diagram? what is the procedure for checking the connection?
LET ME NOW MORE ABOUT icu and ics for circuit breaker. how we calculate the rating of circuit breaker and i c u and ics values