Explain difference between aluminium coductor & copper
coductor.
Answer Posted / madhusudhana
Conductivity of Aluminium is 0.6 times that of copper and its tensile strength is 0.4 times that of of copper. Despite these drawbacks, Aluminium is widely used owing to its low cost.
| Is This Answer Correct ? | 6 Yes | 2 No |
Post New Answer View All Answers
How will polarity test of Dy5 Transformer ?
The metal-enclosed switchgear and controlgear is subdivided into three types: 1. metal-clad switchgear and controlgear; 2. compartmented switchgear and controlgear 3. cubicle switchgear and controlgear. What is the main differnence between them. State some example.
why high speed tripping relay will be used in tripping circuit why not normal relay
i need to give section engineer (electrical engineer) for RRB. Please suggest some book
Can you explain about TEE protection scheme?
A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.
Define active and passive network?
what is the acceptable limit value for Desolve Gas Analysis/
HOW MANY TYPES OF FUSE?
I don't understand why when we connect high voltage source in DC to electronic motor , we must add capacitor and resistor in parallel ? (I know that we use capacitor because we want to absorb the current that in the first second electronic motor in opposed with current course produce. ) what are the feature of Resistor and in such situation ?
surge tank, hrc fuse, earthing transformer, firm power objective type
Inductor and capacitor........power in one phase and ...... in it another phase.
What happens to voltage when current through the inductor is constant?
how to select diiferent power transformers of same capacity on no load loss and full load loss by economical point of view.?
100 MVA 3-phase alternator with earthed neutral has a reactance of 5 ohms per phase. what will be the fault MVA of generator.