why it is in star to delta form of Synchrounus generator
and delta to star form of Generator Transformer (or step up
transformer)
Answer Posted / suhas
after generating voltage, it has to be transmitted....to
transmit we use delta connection as it needs only 3 wires
which saves money...steppin up of voltage is done to
decrease losses in transmission...so step up transformer
has Y-del connection...in the receiving end(step down) we
can use del-del or del-Y...by using del-Y connection we hv
d flexibility of selecting the 3 phase and 1 phase
voltage... this method is done usually for
distribution...for further transmisssion, in swithing sub
stations, the step down trafo will be del-del....with
tertiary as star.....
| Is This Answer Correct ? | 0 Yes | 4 No |
Post New Answer View All Answers
Define settling time.
what are inductive and capacitive voltage transformers.what are their applications
what happen if generator of micro hydro running at only a small percentage of its capacity, as a comparison, if the diesel generator that runs on only a fraction of its capacity there will be a wet stacking
WHAT IS SITTING AMPS IN OVER-LOAD RELAY FOR 1PH OR 3PH MOTORS?IF ITS NAME PLATE GIVEN MAX AMPS 10AMPS?
in india per day how much power is generated including all power station
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
What are the advantages and disadvantages of closed-loop control system?
what is submersible pump?what is different between motor and sub motor?
1.dg on load alarm/stop alarm... 2.dg on load. piu alarm alarm kaise chek krte hai
can anybody tell me that for p.f. Improvment we use capacitor banks but how to decide its capacitance. As we all know how to calculate kvar but what abt capacitance value
The slip during plugging operation is given by= A 1-s B 2+s C 1+s D 2-s
Can any answer me ,What will be the range of C.T coil for L&T energy meter EM301 used for 180 kva DG set
Why do you have to use Protecion relay with the function MTB ( Mechanical Trip Button ) for electrical system.
Why current shoots up in the secondary on the knee point voltage during saturation test of CT? How core saturation effects the secondary current (while the primary side is open)? What the logic behind this?
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?