How electrical power(MW)is varied OF an A.C Generator in
response to varying steam input to a steam turbine ?
Answer Posted / hareesh
The stator of the generator (after synchronization with grid)
is having a rotating emf and the rotor is having its own
magnetic field. If we increase the steam input, the angle
between the stator emf & rotor magnetic field (called load
angle)will also increase due to the additional torque given to
the rotor by the turbine. In that case the power (MW) will
increase. similarly if we reduce the steam input, the load
angle will reduce and the MW will also reduce.
| Is This Answer Correct ? | 6 Yes | 0 No |
Post New Answer View All Answers
What is the dependency of stiffness on load angle??
3 phase Motor will be given 2 phase after 2 to 5 second we given 3rd phase so Motor Run sum-time in forward or sum time run reverse direction. All time phase sequence is not change. Why motor run in reverse direction? Please Explain........
why we use Test Terminal Block in 11 KV and 33 KV electrical panels.
What is pi controller?
An ISP is granted a block of addresses starting with 150.80.0.0/16. The ISP wants to distribute these blocks to 2600 customers as follows. a) 200 medium size businesses; each needs 16 addresses b) 400 small businesses; each needs 8 addresses c) 2000 households; each needs 4 addresses Design the subblocks and give the slash notation for each subblock. Find out how many addresses are still available after these allocations.
Why do we require transformer with less specific weight if supply frequency is increased?
Difference between RCCB, RCBO and ELMCB.
ASTM D 3455 - Standard Test Methods for Compatibility of Construction Material with Electrical Insulating Oil of Petroleum Origin has been used for Testing Transformer Oils with a product placed in it. Aged Control Oil has a Power Factor of 0.032% at 100°C. Aged Oil with a Test component has a Power Factor of 0.093% at 100°. Is this increase acceptable? If not why? How much increase is acceptable?
how to determine ct ratio in ht vcb?
What is electrical cable termination
What should be the Sandwitch type Al. bus bar capacity for 2 M.W.Gen. set, having continuous full load current- 3463 Amps,ambient temp.- 50 Deg. C., Required temp. raise-20 deg.C., it will run 24 hrs, 365 days on full load, required highly reliable.
why to use freewheeling diode ( diode in revers bias mode) across dc coil
what would u consider to be the basic purchase order information you would need to proceed with a cable inspection assignment?
what is the formula of starting current of 3phase and 1 phase motor???
which type of questions asking for solar companies?