Answer Posted / prashant
The initial momentary surge current demand before a load
resistance of impedance increases to its normal operating
value.
| Is This Answer Correct ? | 5 Yes | 1 No |
Post New Answer View All Answers
What are operating procudures & Safety precautions to be observed while operating OLTC in manual mode ?
Why temperature rise is conducted in bus bars and isolators?
What is critical disruptive voltage?
How to do bus bar short circuit calculation for 230KV/11kv, 60 MVA Substation?
What is process of anneling transformer core
How to measure the earth resistance value in a concrete pavement(flood light area)?
Is any generator is developed which is operated with out diesal or other expensive source?
In layman terms, what is the difference of Dielectric strength and dielectric constant when speaking of an insulating oil
hi can any body send me syllabus of rrb electrical section engg... and past pepar also of any board...
How to calculate no of EARTH PIT? Describe the formula as per IS standard?
We have received supplies of the ordered material. payments against the supplies also released. Where ST paid 4% against form C. Meanwhile it has been observed that 25% of material supplied was defective. Please suggest whether the issuance of C form from our side would be stopped till settlement of liabilities.
in general it is observed in power stations, the tertiary winding is used in higher rating Y-Y auto transformer but not in Y-Y power transformer. is the tertiary winding is compulsory then why it is not using in power transformerÂ
if an insulated power and control cables of a running gas diesel gensets laid direct in an open trench i.e, trench bed is not rcc of a power house in which rain water, spillage water alwas exists and all power control cables remains submerged even when gas gensets of 480 kw each runningin on load. These power &control cables runs from power house to switchgear room through these trenches in which water remains most of the time. pl explain its merit & de-merit
1- XC and the RC time constant are both measures of the reaction of C to a change in ____? 2-The power factor is a numerical ratio with a value between 0 and 1 equal to the ______________ of the phase angle. 3-When V and I are out of phase because of reactance, the product of V times I is called ______________ power 4-For _____________ inductors, the branch currents can be added algebraically. 5- The ______________ power in watts can be calculated as I^2R 6-Calculate XL with L = 30mH and f = 1kHz ( I have Xl=2piFL 2*3.141592653*1kHz*30mH =188 ohms Please check) 7-A parallel RL circuit has the values, R = 5kohms, XL = 5kohms. A voltage source of Vt = 10Vrms is connected in parallel to R and L. Determine the total current, It delivered by the voltage source Vt. 8-A series RC circuit has R = 1Mohm and C = 1microF. How long would it take for the capacitor to fully discharge if it is initially fully charged? 9-A circuit has real power = 300W and an apparent power of 500VA. Determine the power factor and phase angle. 10-The time constant for an LR series circuit is T = 0.1s and R = 10ohms. Calculate the inductance L.
8. A DYNAMOMETER TYPE WATTMETER RESPONDS TO THE.......